Table 21. CA000000 to CA2799FF checkpoints (continued)
v
If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in
the Action column until the problem is solved. If an action solves the problem, you can stop performing the
remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
Progress code
Description
Action
CA00E179
Closing BOOTP
1.
Verify that:
v
The bootp server is correctly configured;
then, retry the operation.
v
The network connections are correct;
then, retry the operation.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
CA00E17B
Microprocessor clock speed
measurement
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
CA00E198
The system is rebooting to enact changes
that were specified in
ibm,client-architecture-support
Go to “Boot problem resolution” on page 190.
CA00E199
The system is rebooting to enact changes
that were specified in the boot image
ELF header
1.
Verify that:
v
The bootp server is correctly configured;
then, retry the operation.
v
The network connections are correct;
then, retry the operation.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
CA00E19A
NVRAM auto-boot? variable not found -
assume FALSE
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
CA00E19B
NVRAM menu? variable not found -
assume FALSE
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
CA00E19D
Create NVRAM node
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
Chapter 2. Diagnostics
111