Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
Error code
Description
Action
BA170211
Setenv/$Setenv parameter error - value
contains a null character
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA170220
Unable to write a variable value to
NVRAM due to lack of free memory in
NVRAM.
1.
Reduce the number of partitions, if
possible, to add more NVRAM memory to
this partition.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA170221
Setenv/$setenv had to delete stored
firmware network boot settings to free
memory in NVRAM.
Enter the adapter and network parameters
again for the network boot or network
installation.
BA170998
NVRAMRC script evaluation error -
command line execution error.
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA180008
PCI device Fcode evaluation error
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA180009
The Fcode on a PCI adapter left a data
stack imbalance
1.
Reseat the PCI adapter card.
2.
Check for adapter firmware updates; then,
install the updates if available.
3.
Check for server firmware updates; then,
install the updates if available.
4.
Replace the PCI adapter card.
5.
If the problem persists:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA180010
PCI probe error, bridge in freeze state
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA180011
PCI bridge probe error, bridge is not
usable
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.