Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
Error code
Description
Action
BA201001
The serial interface dropped data
packets
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA201002
The serial interface failed to open
1.
Go to “Checkout procedure” on page 184.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
BA201003
The firmware failed to handshake
properly with the serial interface
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA210000
Partition firmware reports a default
catch
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA210001
Partition firmware reports a stack
underflow was caught
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA210002
Partition firmware was ready before
standout was ready
1.
Reboot the blade server.
2.
If the problem persists:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
Chapter 2. Diagnostics