Table 14. B200xxxx Logical partition SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Reference Code
Description
Action
B2008112
During the startup of a partition, a
failure occurred; the startup will not
continue.
Check for server firmware updates; then, install the
updates if available.
B2008113
During the startup of a partition, an
error occurred while mapping
memory for the partition startup.
Check for server firmware updates; then, install the
updates if available.
B2008114
During the startup of a partition,
there was a failure verifying the
VPD for the partition resources
during startup.
Check for server firmware updates; then, install the
updates if available.
B2008115
During the startup of a partition,
there was a low level
partition-to-partition communication
failure.
Check for server firmware updates; then, install the
updates if available.
B2008117
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Check for server firmware updates; then, install the
updates if available.
B2008121
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Go to “Isolating firmware problems” on page 218.
B2008123
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Go to “Isolating firmware problems” on page 218.
B2008125
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Go to “Isolating firmware problems” on page 218.
B2008127
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Go to “Isolating firmware problems” on page 218.
B2008129
During the startup of a partition, the
partition did not start up due to a
system firmware error.
Go to “Isolating firmware problems” on page 218.
B200813A
There was a problem establishing a
console.
Go to “Isolating firmware problems” on page 218.
B2008140
Informational system log entry only.
No corrective action is required.
B2008141
Informational system log entry only.
No corrective action is required.
B2008142
Informational system log entry only.
No corrective action is required.
B2008143
Informational system log entry only.
No corrective action is required.
B2008144
Informational system log entry only.
No corrective action is required.
B2008145
Informational system log entry only.
No corrective action is required.
B2008150
System firmware detected an error.
Collect a platform dump and then go to “Isolating
firmware problems” on page 218.
Chapter 2. Diagnostics
37