Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
252B-719
252B
Device bus termination power lost or not detected.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
252B-720
252B
Adapter detected device bus failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
252B-721
252B
Temporary adapter detected device bus failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
252B-722
252B
Device bus interface problem.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
252B-723
252B
Device bus interface problem.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
254E-201
254E 221
Adapter configuration error. Go to “Performing the checkout procedure” on page
184.
254E-601
254
Error log analysis indicates adapter failure. Go to “Performing the checkout
procedure” on page 184.
254E-602
254
Error log analysis indicates an error attention condition. Go to “Performing the
checkout procedure” on page 184.
254E-603
254
Error log analysis indicates that the microcode could not be loaded on the adapter.
Go to “Performing the checkout procedure” on page 184.
254E-604
254
Error log analysis indicates a permanent adapter failure. Go to “Performing the
checkout procedure” on page 184.
254E-605
254
Error log analysis indicates permanent adapter failure is reported on the other port
of this adapter. Go to “Performing the checkout procedure” on page 184.
254E-606
254
Error log analysis indicates adapter failure. Go to “Performing the checkout
procedure” on page 184.
254E-701
254E 221
Error log analysis indicates permanent adapter failure. Go to “Performing the
checkout procedure” on page 184.
254E-702
254E 221
Error log analysis indicates permanent adapter failure is reported on the other port
of this adapter. Go to “Performing the checkout procedure” on page 184.
2567-xxx
2567
USB integrated system-board and chassis assembly. Go to “Performing the checkout
procedure” on page 184.
144
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)