Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
651-66A
2CE
Correctable error threshold exceeded. Go to “Performing the checkout procedure” on
page 184.
651-66B
2CC
Correctable error threshold exceeded. Go to “Performing the checkout procedure” on
page 184.
651-674
302
Failed memory module. Go to “Performing the checkout procedure” on page 184.
651-675
303
Failed memory module. Go to “Performing the checkout procedure” on page 184.
651-676
304
Failed memory module. Go to “Performing the checkout procedure” on page 184.
651-679
2CD
Failed memory module. Go to “Performing the checkout procedure” on page 184.
651-67A
2CE
Failed memory module. Go to “Performing the checkout procedure” on page 184.
651-67B
2CC
Failed memory module. Go to “Performing the checkout procedure” on page 184.
651-685
303
Memory module has no matched pair. The most probable failure is the memory
module paired with the memory module identified by the location code. Go to
“Performing the checkout procedure” on page 184.
651-686
304
Memory module has no matched pair. The most probable failure is the memory
module paired with the memory module identified by the location code. Go to
“Performing the checkout procedure” on page 184.
651-710
214 2C4
System bus parity error. Go to “Performing the checkout procedure” on page 184.
651-711
210 2C4
System bus parity error. Go to “Performing the checkout procedure” on page 184.
651-712
214
System bus parity error. Go to “Performing the checkout procedure” on page 184.
651-713
214
System bus protocol/transfer error. Go to “Performing the checkout procedure” on
page 184.
651-714
2C4
System bus protocol/transfer error. Go to “Performing the checkout procedure” on
page 184.
651-715
2C4
System bus protocol/transfer error. Go to “Performing the checkout procedure” on
page 184.
651-720
2C7 214
Uncorrectable memory error. Go to “Performing the checkout procedure” on page
184.
651-721
2C6 2C7 214 Uncorrectable memory error. Go to “Performing the checkout procedure” on page
651-722
2C4
System bus parity error. Go to “Performing the checkout procedure” on page 184.
651-723
2C4
System bus protocol/transfer error. Go to “Performing the checkout procedure” on
page 184.
651-724
292
I/O host bridge time-out error. Go to “Performing the checkout procedure” on page
184.
651-725
292
I/O host bridge address/data parity error. Go to “Performing the checkout
procedure” on page 184.
651-726
Software
I/O host bridge timeout caused by software. This error is caused by a software or
operating system attempt to access an invalid memory address. Go to “Performing
the checkout procedure” on page 184.
651-731
2C8
Intermediate or system bus address parity error. Go to “Performing the checkout
procedure” on page 184.
651-732
2C8
Intermediate or system bus data parity error. Go to “Performing the checkout
procedure” on page 184.
651-733
2C8
Intermediate or system bus address parity error. Go to “Performing the checkout
procedure” on page 184.
Chapter 2. Diagnostics
133