Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
2E10-605
2E10
Error Log Analysis indicates permanent adapter failure is reported on the other port
of this adapter.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
2E10-606
2E10
Error Log Analysis indicates adapter failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
2E10-701
2E10 221
Error Log Analysis indicates permanent adapter failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
2E10-702
2E10 221
Error Log Analysis indicates permanent adapter failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
2E13-201
2E13 221
Adapter configuration error.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
2E13-601
2E13
Error Log Analysis indicates adapter failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
2E13-602
2E13
Error Log Analysis indicates an Error Attention condition.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
2E13-603
2E13
Error Log Analysis indicates that the microcode could not be loaded on the adapter.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
2E13-604
2E13
Error Log Analysis indicates a permanent adapter failure.
1.
Check the BladeCenter management-module event log. If an error was recorded
by the system, see “POST progress codes (checkpoints)” on page 84.
2.
Replace any parts reported by the diagnostic program.
3.
Replace the system-board.
150
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)