Table 15. B700xxxx Licensed internal code SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
Description
Action
0601
Informational system log entry only.
No corrective action is required.
Note:
This code and associated data can be
used to determine why the time of day for a
partition was lost.
0602
System firmware detected an error
condition.
1.
Collect the event log information.
2.
Go to “Isolating firmware problems” on
page 218.
0611
There is a problem with the system
hardware clock; the clock time is
invalid.
Use the operating system to set the system
clock.
0621
Informational system log entry only.
No corrective action is required.
0641
System firmware detected an error.
1.
Collect the platform dump information.
2.
Go to “Isolating firmware problems” on
page 218.
0650
System firmware detected an error.
Resource management was unable to
allocate main storage. A platform dump
was initiated.
1.
Collect the event log.
2.
Collect the platform dump data.
3.
Collect the partition configuration
information.
4.
Go to “Isolating firmware problems” on
page 218.
0651
The system detected an error in the
system clock hardware
Replace the system-board and chassis
assembly, as described in “Replacing the FRU
system-board and chassis assembly” on page
260.
0803
Informational system log entry only.
No corrective action is required.
0804
Informational system log entry only.
No corrective action is required.
0A00
Informational system log entry only.
No corrective action is required.
0A01
Informational system log entry only.
No corrective action is required.
0A10
Informational system log entry only.
No corrective action is required.
1150
Informational system log entry only.
No corrective action is required.
1151
Informational system log entry only.
No corrective action is required.
1152
Informational system log entry only.
No corrective action is required.
1160
Service processor failure
1.
Go to “Isolating firmware problems” on
page 218.
2.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
1161
Informational system log entry only.
No corrective action is required.
1730
The VPD for the system is not what was
expected at startup.
Replace the management card, as described in
“Removing the tier 2 management card” on
page 255 and “Installing the tier 2 management
card” on page 256.
Chapter 2. Diagnostics
41