Table 15. B700xxxx Licensed internal code SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
Description
Action
5302
An unsupported Preferred Operating
System was detected.
The Preferred Operating System
specified is not supported. The IPL will
not continue.
Work with IBM support to select a supported
Preferred Operating System; then, re-IPL the
system.
5303
An unsupported Preferred Operating
System was detected.
The Preferred Operating System
specified is not supported. The IPL will
continue.
Work with IBM support to select a supported
Preferred Operating System; then, re-IPL the
system.
5304
The number of available World Wide
Port Names (WWPN) is low.
https://www-912.ibm.com/supporthome.nsf/
document/51455410
5305
The number of available World Wide
Port Names (WWPN) is low.
https://www-912.ibm.com/supporthome.nsf/
document/51455410
5400
System firmware detected a problem
with a processor.
Replace the system-board and chassis
assembly, as described in “Replacing the FRU
system-board and chassis assembly” on page
260.
5442
System firmware detected an error.
Replace the system-board and chassis
assembly, as described in “Replacing the FRU
system-board and chassis assembly” on page
260.
54DD
Informational system log entry only.
No corrective action is required.
5600
Informational system log entry only.
No corrective action is required.
5601
System firmware failure. There was a
problem initializing, reading, or using
system location codes.
Go to “Isolating firmware problems” on page
218.
5602
The system has out-of-date VPD LIDs.
Check for server firmware updates; then,
install the updates if available.
5603
Enclosure feature code and/or serial
number not valid.
Verify that the machine type, model, and serial
number are correct for this server.
6900
PCI host bridge failure
1.
Replace the system-board, as described in
“Replacing the FRU system-board and
chassis assembly” on page 260.
2.
If the problem persists, use the “PCI
expansion card (PIOCARD) problem
isolation procedure” on page 194 to
determine the failing component.
6906
System bus error
Replace the system-board and chassis
assembly, as described in “Replacing the FRU
system-board and chassis assembly” on page
260.
44
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)