Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
Error code
Description
Action
BA060022
The environment variable “boot-device”
contained an entry that exceeded 255
characters in length
1.
Using the SMS menus, set the boot list to
the default boot list.
2.
Shut down; then, start up the blade server.
3.
Use SMS menus to customize the boot list
as required.
4.
If the problem persists:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA060030
Logical partitioning with shared
processors is enabled and the operating
system does not support it.
1.
Install or boot a level of the operating
system that supports shared processors.
2.
Disable logical partitioning with shared
processors in the operating system.
3.
If the problem remains:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA060060
The operating system expects an IOSP
partition, but it failed to make the
transition to alpha mode.
1.
Verify that:
v
The alpha-mode operating system image
is intended for this partition.
v
The configuration of the partition
supports an alpha-mode operating
system.
2.
If the problem remains:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA060061
The operating system expects a
non-IOSP partition, but it failed to make
the transition to MGC mode.
1.
Verify that:
v
The alpha-mode operating system image
is intended for this partition.
v
The configuration of the partition
supports an alpha-mode operating
system.
2.
If the problem remains:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
62