Table 16. BA000010 to BA400002 Partition firmware SRCs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
Error code
Description
Action
BA210103
There was a communication failure
between partition firmware and the
hypervisor. There was a failing return
code with the lpevent acknowledgement
from the hypervisor.
1.
Review the event log for errors that
occurred around the time of this error.
2.
Correct any errors that are found and
reboot the blade server.
3.
If the problem persists:
a.
Reboot the blade server.
b.
If the problem persists:
1)
Go to “Checkout procedure” on
page 184.
2)
Replace the system-board, as
described in “Replacing the FRU
system-board and chassis assembly”
on page 260.
BA220010
There was a partition firmware error
during a USB hotplug probing. USB
hotplug may not work properly on this
partition.
1.
Look for EEH-related errors in the event
log.
2.
Resolve any EEH event log entries that are
found.
3.
Correct any errors that are found and
reboot the blade server.
4.
If the problem persists:
a.
Go to “Checkout procedure” on page
184.
b.
Replace the system-board, as described
in “Replacing the FRU system-board
and chassis assembly” on page 260.
BA220020
CRQ registration error; partner vslot
may not be valid
Verify that this client virtual slot device has a
valid server virtual slot device in a hosting
partition.
BA278001
Failed to flash firmware: invalid image
file
Download a new firmware update image and
retry the update.
BA278002
Flash file is not designed for this
platform
Download a new firmware update image and
retry the update.
BA278003
Unable to lock the firmware update lid
manager
1.
Restart the blade server.
2.
Verify that the operating system is
authorized to update the firmware. If the
system is running multiple partitions, verify
that this partition has service authority.
BA278004
An invalid firmware update lid was
requested
Download a new firmware update image and
retry the update.
BA278005
Failed to flash a firmware update lid
Download a new firmware update image and
retry the update.
BA278006
Unable to unlock the firmware update
lid manager
Restart the blade server.
78
Power Systems: Problem Determination and Service Guide for the IBM Power PS700 (8406-70Y)