Table 25. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
Description and Action
651-613
D01
External cache ECC single-bit error. Go to “Performing the checkout procedure” on
page 184.
651-614
214
System bus time-out error. Go to “Performing the checkout procedure” on page 184.
651-615
292
Time-out error waiting for I/O. Go to “Performing the checkout procedure” on page
184.
651-619
Error log analysis indicates an error detected by the CPU. Use failing function codes
and the physical location codes from the diagnostic problem report screen to
determine the FRUs.
651-621
2C6
ECC correctable error. Go to “Performing the checkout procedure” on page 184.
651-623
2C6
Correctable error threshold exceeded. Go to “Performing the checkout procedure” on
page 184.
651-624
214
Memory control subsystem internal error. Go to “Performing the checkout
procedure” on page 184.
651-625
214
Memory address error (invalid address or access attempt). Go to “Performing the
checkout procedure” on page 184.
651-626
214
Memory data error (bad data going to memory). Go to “Performing the checkout
procedure” on page 184.
651-627
214
System bus time-out error. Go to “Performing the checkout procedure” on page 184.
651-628
210
System bus protocol/transfer error. Go to “Performing the checkout procedure” on
page 184.
651-629
210
Error log analysis indicates an error detected by the memory controller. Go to
“Performing the checkout procedure” on page 184.
651-632
308
Internal device error. Go to “Performing the checkout procedure” on page 184.
651-639
210
Error log analysis indicates an error detected by the I/O. Using the problem
determination procedure, failing function codes, and the physical location codes
from the diagnostic problem report to determine the FRUs.
651-640
2D5
I/O general bus error. Go to “Performing the checkout procedure” on page 184.
651-641
2D6
Secondary I/O general bus error. Go to “Performing the checkout procedure” on
page 184.
651-642
2D3
Internal service processor memory error. Go to “Performing the checkout procedure”
on page 184.
651-643
2D3
Internal service processor firmware error. Go to “Performing the checkout
procedure” on page 184.
651-644
2D3
Other internal service processor hardware error. Go to “Performing the checkout
procedure” on page 184.
651-659
2CD
ECC correctable error. Go to “Performing the checkout procedure” on page 184.
651-65A
2CE
ECC correctable error. Go to “Performing the checkout procedure” on page 184.
651-65B
2CC
ECC correctable error. Go to “Performing the checkout procedure” on page 184.
651-664
302
Correctable error threshold exceeded. Go to “Performing the checkout procedure” on
page 184.
651-665
303
Correctable error threshold exceeded. Go to “Performing the checkout procedure” on
page 184.
651-666
304
Correctable error threshold exceeded. Go to “Performing the checkout procedure” on
page 184.
651-669
2CD
Correctable error threshold exceeded. Go to “Performing the checkout procedure” on
page 184.
132