Table 27. A00-FF0 through A24-xxx SRNs (continued)
SRN
Description
FRU/action
A1D-19x
A non-critical error has been detected, a
service processor error accessing real
time clock/time-of-day clock.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-20x
A non-critical error has been detected:
Service processor error accessing scan
controller/hardware.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-21x
A non-critical error has been detected, a
service processor detected error with
time-of-day clock backup battery.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-23x
A non-critical error has been detected:
Loss of heart beat from Service
Processor.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-24x
A non-critical error has been detected, a
service processor detected a
surveillance time-out.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-29x
A non-critical error has been detected, a
service process error accessing power
control network.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-30x
A non-critical error has been detected:
Non-supported hardware.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.
A1D-31x
A non-critical error has been detected:
Error detected while handling an
attention/interrupt from the system
hardware.
1.
Check the BladeCenter management-module
event log; if an error was recorded by the
system, see “POST progress codes
(checkpoints)” on page 84.
2.
If no entry is found, Replace the
system-board.