v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 3, “Parts listing, Type 8406,” on page 229 to determine which components are CRUs and which
components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Isolation
Procedure Code
Symptom
Action
FSPSP54
A processor
over-temperature has
been detected. Check
for any
environmental issues
before replacing any
parts.
1.
Measure the ambient room temperature to see if it is in within the
upper limit of the normal operating range. The upper limit is less
than 35 degrees C or 95 degrees F. If the temperature exceeds this
limit, you must bring down the room temperature until it is within
the limit. When the temperature is within range, retry the operation.
2.
If the temperature is within the acceptable range, check the front and
rear of the BladeCenter unit to verify that the each is free of
obstructions that would impede the airflow. If there are obstructions,
you must clear the obstructions. Also clean the air inlets and exits in
the BladeCenter unit drawer as required. If you cleared obstructions,
retry the operation.
3.
Verify that the fans in the BladeCenter unit are working correctly. If
not, replace fans that are not turning or that are turning slowly. If
you replace fans, wait for the unit to cool and retry the operation.
4.
If the cooling components are functioning correctly, replace the
system board and chassis assembly, as described in “Replacing the
FRU system-board and chassis assembly” on page 260.
IOHUB Symbolic
CRU
The failing
component is the
RIO/HSL NIC on the
IPL path.
Replace the system board and chassis assembly, as described in
“Replacing the FRU system-board and chassis assembly” on page 260.
IOBRDG
Symbolic CRU
The failing
component is the
RIO/HSL I/O bridge
on the IPL path.
Replace the system board and chassis assembly, as described in
“Replacing the FRU system-board and chassis assembly” on page 260.
MEMBRD
Symbolic CRU
The failing
component is the
board the memory
DIMMs plug into.
Replace the system board and chassis assembly, as described in
“Replacing the FRU system-board and chassis assembly” on page 260.
MEMCTLR
Symbolic CRU
The failing
component is one of
the memory
controllers.
Replace the system board and chassis assembly, as described in
“Replacing the FRU system-board and chassis assembly” on page 260.
Chapter 2. Diagnostics
211