Accessing
System
Log
Error
Information
Note:
The
system
attention
LED
can
be
reset
by
following
the
procedures
described
in
“Resetting
the
System
Attention
LED.”
When
an
error
is
detected
by
the
system,
information
about
the
error
is
stored
in
error
logs.
The
following
sections
explain
how
to
access
the
logs
that
are
available
on
a
system.
The
error
logs
are
accessed
from
the
console
that
is
used
to
manage
the
system.
From
the
following
console
descriptions,
go
to
the
instructions
under
the
heading
that
best
describes
the
system
on
which
you
are
working:
v
“Accessing
Errors
when
a
System
is
Running
AIX.”
v
“Accessing
Errors
when
a
System
is
Running
Linux.”
Accessing
Errors
when
a
System
is
Running
AIX
If
the
system
attention
LED
comes
on
and
the
system
is
running
AIX,
do
the
following
to
access
the
error
logs:
1.
If
the
system
is
operational,
examine
the
AIX
error
log
to
see
if
user
intervention
is
required.
2.
If
the
system
is
powered
off,
examine
the
service
processor
error
log
for
entries.
3.
If
the
AIX
error
log
indicates
service
support
is
required,
or
there
are
entries
in
the
service
processor
error
log,
go
to
“Entry
MAP”
on
page
41
with
the
information
noted
from
the
error
log.
Accessing
Errors
when
a
System
is
Running
Linux
If
the
system
attention
LED
comes
on
and
the
system
is
running
Linux
and
is
not
attached
to
an
HMC,
do
one
of
the
following:
v
If
you
performed
“Step
1321-43”
on
page
70
in
“MAP
1321:
Quick
Entry
MAP
for
Systems
with
Service
Focal
Point”
on
page
61,
return
to
“Step
1321-43”
on
page
70
to
process
any
other
symptoms.
v
If
you
have
not
performed
any
of
the
steps
in
“MAP
1321:
Quick
Entry
MAP
for
Systems
with
Service
Focal
Point”
on
page
61,
go
to
step
“Step
1321-1”
on
page
61
and
perform
the
procedures
in
the
MAP.
Resetting
the
System
Attention
LED
Complete
one
of
the
following
procedures
to
reset
your
attention
LED.
Note:
Because
this
system
runs
a
single
operating
system
in
a
full
system
partition
and
does
not
connect
to
an
HMC,
references
to
Service
Focal
Point
software
do
not
apply.
If
you
were
directed
here
to
reset
the
system
attention
LED,
use
the
following
procedures.
Resetting
the
LED
when
a
System
is
Running
AIX
As
a
user
with
root
authority
or
CE
login,
type
diag
on
the
AIX
command
line,
and
do
the
following:
1.
Select
Task
Selection
.
2.
On
the
Task
Selection
Menu,
select
Identify
and
Attention
Indicators
.
3.
When
the
list
of
LEDs
displays,
use
the
cursor
to
highlight
Set
System
Attention
Indicator
to
Normal
.
4.
Press
Enter,
and
then
press
F7
to
commit.
This
action
turns
off
the
LED.
If
the
system
is
powered
off,
access
the
service
processor
menus.
From
the
service
processor
main
menu,
do
the
following:
1.
Select
System
Information
Menu
.
2.
Select
LED
Control
Menu
.
3.
Select
Clear
System
Attention
Indicator
.
This
action
turns
off
the
LED.
38
IntelliStation
POWER
9114
Model
275
Service
Guide
Summary of Contents for 9114-275 - IntelliStation POWER 275
Page 1: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 2: ......
Page 3: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 14: ...xii IntelliStation POWER 9114 Model 275 Service Guide ...
Page 16: ...xiv IntelliStation POWER 9114 Model 275 Service Guide ...
Page 50: ...32 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 58: ...40 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 81: ...Yes Go to Step 1321 16 on page 64 Chapter 3 Maintenance Analysis Procedures MAPs 63 ...
Page 210: ...192 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 246: ...228 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 320: ...System Parts 302 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 330: ...312 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 332: ...314 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 336: ...318 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 340: ...322 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 375: ......