![IBM 9114-275 - IntelliStation POWER 275 Service Manual Download Page 295](http://html.mh-extra.com/html/ibm/9114-275-intellistation-power-275/9114-275-intellistation-power-275_service-manual_606733295.webp)
5.
Press
F3
to
go
back
to
the
first
menu
and
select
System
Storage
Management
(Physical
and
Logical
Storage)
and
press
Enter.
6.
Select
Logical
Volume
Manager
and
press
Enter.
7.
Select
Volume
Groups
and
press
Enter.
8.
Select
Set
Characteristics
of
a
Volume
Group
and
press
Enter.
9.
Select
Add
a
Physical
Volume
to
a
Volume
Group
.
10.
Fill
in
the
fields
for
the
drive
you
are
adding
to
the
system.
Press
F4
for
a
list
of
selections.
11.
See
the
AIX
System
Management
Guide:
Operating
System
and
Devices
to
finish
the
drive
configuration.
12.
Press
F10
to
exit
smitty.
Removing
a
Hot-Swap
Disk
Drive
Attention:
Before
you
perform
the
following
procedure,
back
up
the
data
for
the
drive
you
are
removing,
and
ensure
that
the
drive
has
been
removed
from
the
configuration.
Physically
removing
a
hot-swap
drive
from
the
system
before
it
has
been
removed
from
the
system
configuration
can
cause
unrecoverable
data
corruption.
Refer
to
“Deconfiguring
a
Disk
Drive
for
Removal”
on
page
276.
Attention:
The
Linux
operating
system
does
not
support
these
hot-swappable
procedures.
Also,
Linux
does
not
support
hot-swapping
any
hot-swappable
device.
A
system
with
Linux
installed
must
be
shut
down
and
powered
off
before
replacing
any
disk
drive.
Use
the
non-hot-swappable
procedures
when
replacing
a
disk
drive
with
the
Linux
operating
system
installed.
To
remove
a
hot-swap
disk
drive,
do
the
following:
1.
Before
removing
the
disk,
ensure
all
data
has
been
saved.
2.
Deconfigure
the
drive
you
are
removing
from
the
system.
See
“Deconfiguring
a
Disk
Drive
for
Removal”
on
page
276.
3.
Open
the
front
bezel
door.
4.
Locate
the
hot-swap
disk
drive
you
want
to
remove.
Note
the
disk
drive’s
bay
location
so
that
it
can
be
replaced
in
the
same
slot.
If
you
are
removing
a
faulty
disk
drive,
a
lit
amber
LED
located
at
the
front
of
each
disk
drive
will
help
you
isolate
the
faulty
drive.
5.
Log
in
as
root
user.
6.
At
the
command
line,
type
smitty
.
7.
Select
System
Storage
Management
(Physical
and
Logical
Storage)
.
8.
Select
Removable
Disk
Management
.
9.
Select
Remove
a
Disk
.
10.
Select
the
desired
disk
from
the
list
on
the
screen
and
press
Enter.
11.
Remove
the
disk
drive
by
placing
the
disk
drive
release
handle
into
the
open
position
(perpendicular
to
the
drive)
and
pulling
the
hot-swap
disk
drive
away
from
the
bay.
The
lit
LED
on
the
disk
drive
will
turn
off
when
the
disk
drive
is
removed.
Chapter
9.
Removal
and
Replacement
Procedures
277
Summary of Contents for 9114-275 - IntelliStation POWER 275
Page 1: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 2: ......
Page 3: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 14: ...xii IntelliStation POWER 9114 Model 275 Service Guide ...
Page 16: ...xiv IntelliStation POWER 9114 Model 275 Service Guide ...
Page 50: ...32 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 58: ...40 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 81: ...Yes Go to Step 1321 16 on page 64 Chapter 3 Maintenance Analysis Procedures MAPs 63 ...
Page 210: ...192 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 246: ...228 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 320: ...System Parts 302 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 330: ...312 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 332: ...314 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 336: ...318 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 340: ...322 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 375: ......