Table
5.
Firmware
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
20EE
000C
Description:
Pointer
to
the
operating
system
not
found
in
non-volatile
storage.
Action:
Values
normally
found
in
non-volatile
storage
that
point
to
the
location
of
an
operating
system
were
not
found.
This
can
happen
for
two
reasons,
either
your
installed
operating
system
does
not
support
storing
the
values
or
some
event
occurred
that
caused
the
system
to
lose
non-volatile
storage
information
(drainage
or
replacement
of
the
battery).
If
you
are
running
AIX,
this
information
can
be
reconstructed
by
running
the
bootlist
command
specifying
the
device
that
the
operating
system
is
installed
on.
Refer
to
your
AIX
documentation
for
the
exact
syntax
and
usage
of
the
bootlist
command.
To
boot
the
operating
system
so
that
the
above-mentioned
values
can
be
reconstructed,
power
off
the
system
and
power
it
on
again.
This
should
cause
the
system
to
look
for
the
operating
system
in
the
devices
contained
in
the
custom
boot
list
or
in
the
default
boot
list,
depending
on
the
condition
of
the
system.
If
this
is
not
successful,
use
the
System
Management
Services
Menus
to
modify
the
boot
sequence
(also
known
as
boot
list)
to
include
devices
that
are
known
to
contain
a
copy
of
the
operating
system.
For
example,
select
a
hard
disk
known
to
have
a
copy
of
the
operating
system
as
the
first
and
only
device
in
the
boot
sequence
(boot
list)
and
attempt
to
boot
again.
If
the
problem
persists,
replace
the
system
unit
backplane.
Location:
U0.1-P1.
20EE
000E
Unable
to
execute
the
open
firmware
method.
1.
Reboot
the
system.
2.
Reflash
the
system
with
the
latest
level
of
system
firmware.
3.
Call
service
support.
20EE
000F
Unable
to
find
the
package
node.
1.
Reboot
the
system.
2.
Reflash
the
system
with
the
latest
level
of
system
firmware.
3.
Call
service
support.
20EE
0010
Unable
to
execute
the
root
VPD
method.
1.
Reboot
the
system.
2.
Reflash
the
system
with
the
latest
level
of
system
firmware.
3.
Call
service
support.
20EE
0011
Unable
to
execute
the
VPD
method.
1.
Reboot
the
system.
2.
Reflash
the
system
with
the
latest
level
of
system
firmware.
3.
Call
service
support.
20EE
0012
Unable
to
execute
the
mem-dimm-VPD
method
1.
Reboot
the
system.
2.
Reflash
the
system
with
the
latest
level
of
system
firmware.
3.
Call
service
support.
20EE
0013
Unable
to
allocate
memory
for
VPD.
1.
Reboot
the
system.
2.
Reflash
the
system
with
the
latest
level
of
system
firmware.
3.
Call
service
support.
20EE
0014
Unable
to
allocate
memory
for
location
codes.
The
system
firmware
may
be
corrupted.
Chapter
5.
Error
Code
to
FRU
Index
149
Summary of Contents for 9114-275 - IntelliStation POWER 275
Page 1: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 2: ......
Page 3: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 14: ...xii IntelliStation POWER 9114 Model 275 Service Guide ...
Page 16: ...xiv IntelliStation POWER 9114 Model 275 Service Guide ...
Page 50: ...32 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 58: ...40 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 81: ...Yes Go to Step 1321 16 on page 64 Chapter 3 Maintenance Analysis Procedures MAPs 63 ...
Page 210: ...192 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 246: ...228 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 320: ...System Parts 302 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 330: ...312 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 332: ...314 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 336: ...318 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 340: ...322 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 375: ......