Step
1548-12
The
system
is
working
correctly
with
this
configuration.
One
of
the
disk
drives
that
you
removed
from
the
disk
drive
backplanes
may
be
defective.
1.
Make
sure
the
diagnostic
CD-ROM
is
inserted
into
the
CD-ROM
drive.
2.
Turn
off
the
power
and
remove
the
power
cords.
3.
Install
a
disk
drive
in
a
disk
drive
backplane.
4.
Plug
in
the
power
cords
and
wait
for
the
OK
prompt
to
display
on
the
operator
panel
display.
5.
Turn
on
the
power.
6.
After
the
word
keyboard
is
displayed,
press
the
number
5
key
on
either
the
directly
attached
keyboard
or
on
an
ASCII
terminal
keyboard.
7.
Enter
the
appropriate
password
if
you
are
prompted
to
do
so.
Is
the
Please
define
the
System
Console
screen
displayed?
No
Exchange
the
FRUs
that
have
not
been
exchanged,
in
the
following
order:
1.
Last
disk
drive
installed
2.
Disk
drive
backplane
where
the
disk
drive
was
installed
Repeat
this
step
until
the
defective
FRU
is
identified
or
all
the
FRUs
have
been
exchanged.
If
the
symptom
did
not
change
and
all
the
FRUs
have
been
exchanged,
call
service
support
for
assistance.
If
the
symptom
has
changed,
check
for
loose
cards,
cables,
and
obvious
problems.
If
you
do
not
find
a
problem,
go
to
the
“Quick
Entry
MAP”
on
page
43
and
follow
the
instructions
for
the
new
symptom.
Yes
Repeat
this
step
with
all
disk
drives
that
were
installed
in
the
disk
drive
backplanes.
If
the
system
has
a
diskette
drive,
go
to
“Step
1548-13.”
Go
to
“Step
1548-14”
on
page
97.
Step
1548-13
The
system
is
working
correctly
with
this
configuration.
The
diskette
drive
may
be
defective.
1.
Make
sure
the
diagnostic
CD-ROM
is
inserted
into
the
CD-ROM
drive.
2.
Turn
off
the
power
and
remove
the
power
cords.
3.
Plug
the
diskette
drive
cable
into
the
diskette
drive
connector
on
the
CEC
backplane.
4.
Connect
the
signal
and
power
connectors
to
the
diskette
drive.
5.
Plug
in
the
power
cords
and
wait
for
the
OK
prompt
to
display
on
the
operator
panel
display.
6.
Turn
on
the
power.
7.
After
the
word
keyboard
displays,
press
the
number
5
key
on
either
the
directly
attached
keyboard
or
on
an
ASCII
terminal
keyboard.
8.
Enter
the
appropriate
password
if
you
are
prompted
to
do
so.
Is
the
Please
define
the
System
Console
screen
displayed?
NO
One
of
the
FRUs
remaining
in
the
system
is
defective.
Exchange
the
FRUs
that
have
not
been
exchanged,
in
the
following
order:
1.
Diskette
drive
2.
Diskette
drive
cable
3.
CEC
backplane
(see
notes
on
page
41)
Repeat
this
step
until
the
defective
FRU
is
identified
or
all
the
FRUs
have
been
exchanged.
96
IntelliStation
POWER
9114
Model
275
Service
Guide
Summary of Contents for 9114-275 - IntelliStation POWER 275
Page 1: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 2: ......
Page 3: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 14: ...xii IntelliStation POWER 9114 Model 275 Service Guide ...
Page 16: ...xiv IntelliStation POWER 9114 Model 275 Service Guide ...
Page 50: ...32 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 58: ...40 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 81: ...Yes Go to Step 1321 16 on page 64 Chapter 3 Maintenance Analysis Procedures MAPs 63 ...
Page 210: ...192 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 246: ...228 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 320: ...System Parts 302 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 330: ...312 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 332: ...314 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 336: ...318 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 340: ...322 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 375: ......