Symptom
Action
Service
Actions
You
have
parts
to
exchange
or
a
corrective
action
to
perform.
1.
Go
to
Chapter
9,
“Removal
and
Replacement
Procedures,”
on
page
243.
2.
Go
to
″
MAP
0410:
Repair
Checkout
″
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems
.
You
need
to
verify
that
a
part
exchange
or
corrective
action
corrected
the
problem.
Go
to
″
MAP
0410:
Repair
Checkout
″
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems
.
You
need
to
verify
correct
system
operation.
Go
to
″
MAP
0410:
Repair
Checkout
″
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems
.
The
system
attention
LED
on
the
operator
panel
is
on.
The
system
attention
LED
on
the
operator
panel
is
on.
Go
to
“System
Attention
LED”
on
page
34
and
perform
the
listed
actions.
OK
does
not
appear
in
the
operator
panel
display
before
pressing
the
power-on
button.
Other
symptoms
appear
in
the
operator
panel
display
or
LEDs
before
the
power
on
button
is
pressed.
A
bouncing
or
scrolling
ball
remains
on
the
operator
panel
display,
or
the
operator
panel
display
is
filled
with
dashes
or
blocks.
Verify
the
operator
panel
cable
from
the
operator
panel
to
the
CEC
backplane
is
connected
and
properly
seated
at
both
ends.
If
an
ASCII
terminal
is
available,
connect
it
to
the
system
through
serial
port
1.
v
If
the
service
processor
menu
is
displayed,
replace
the
operator
panel
assembly,
location
U0.1-L1.
Refer
to
“Operator
Panel
and
Power
Cable”
on
page
283.
v
If
the
service
processor
menu
is
not
displayed,
replace
the
service
processor,
location:
U0.1-P1-X1
(See
notes
on
page
41).
If
an
ASCII
terminal
is
not
available,
replace
the
following
one
at
a
time.
1.
Operator
panel
assembly,
location:
U0.1-L1.
Refer
to
“Operator
Panel
and
Power
Cable”
on
page
283.
2.
Service
processor,
location:
U0.1-P1-X1.
(See
notes
on
page
41).
You
have
a
blank
display
on
the
operator
panel.
Other
LEDs
on
the
operator
panel
appear
to
behave
normally.
1.
Replace
the
operator
panel
assembly,
Location:
U0.1-L1.
Refer
to
“Operator
Panel
and
Power
Cable”
on
page
283.
2.
Replace
the
service
processor,
location:
U0.1-P1-X1.
(See
notes
on
page
41).
You
have
a
blank
display
on
the
operator
panel.
Other
LEDs
on
the
operator
panel
are
off.
Go
to
“MAP
1520:
Power”
on
page
76.
8-Digit
Error
Codes
You
have
an
8-digit
error
code
displayed
Look
up
the
error
code
in
the
table
in
“Checkpoint
and
Error
Code
Index”
on
page
134.
System
stops
with
an
8-digit
number
displayed
The
system
stops
with
an
8-digit
error
code
displayed
when
booting.
Look
up
the
error
code
in
the
table
in
“Checkpoint
and
Error
Code
Index”
on
page
134.
44
IntelliStation
POWER
9114
Model
275
Service
Guide
Summary of Contents for 9114-275 - IntelliStation POWER 275
Page 1: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 2: ......
Page 3: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 14: ...xii IntelliStation POWER 9114 Model 275 Service Guide ...
Page 16: ...xiv IntelliStation POWER 9114 Model 275 Service Guide ...
Page 50: ...32 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 58: ...40 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 81: ...Yes Go to Step 1321 16 on page 64 Chapter 3 Maintenance Analysis Procedures MAPs 63 ...
Page 210: ...192 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 246: ...228 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 320: ...System Parts 302 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 330: ...312 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 332: ...314 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 336: ...318 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 340: ...322 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 375: ......