Table
5.
Firmware
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
20D1
000D
Function
to
get
time-of-day
failed.
1.
Check
for
system
firmware
updates.
Apply
update
if
available.
2.
Contact
your
next
level
of
support
for
assistance.
20D1
000E
Function
to
get
time-of-day
failed.
1.
Check
for
system
firmware
updates.
Apply
update
if
available.
2.
Contact
your
next
level
of
support
for
assistance.
20D1
000F
Hypervisor
call
to
reset
PHB
or
to
check
for
drawer
existence
failed
1.
Check
for
system
firmware
updates.
Apply
update
if
available.
2.
Contact
your
next
level
of
support
for
assistance.
20D1
0010
Stack
underflow
from
fiber
channel
adapter
1.
Check
for
microcode
updates
for
the
fiber
channel
adapter.
Apply
an
update
if
available.
2.
Check
for
system
firmware
updates.
Apply
an
update
if
available.
3.
Contact
your
next
level
of
support
for
assistance.
20D1
0011
PHB
recovery
was
not
successful.
Open
firmware
received
failure
in
phb-recovery-buff
1.
Check
for
system
firmware
updates.
Apply
update
if
available.
2.
Contact
your
next
level
of
support
for
assistance.
20D1
0012
Attention:
One
of
the
I/O
subsystems
has
been
disconnected
from
the
system.
This
is
indicates
that
an
I/O
subsystem
that
was
previously
in
the
configuration
was
not
found
during
the
current
boot.
If
an
I/O
subsystem
has
been
configuration
has
not
changed,
do
the
following:
1.
If
not
already
booted,
boot
the
system
and
match
the
I/O
subsystem
location
codes
reported
by
the
operating
system
to
the
subsystems
attached
to
the
system
unit.
Check
the
SPCN
and
RIO
cabling
to
the
I/O
subsystems.
If
an
cabling
problem
is
found,
correct
it.
2.
Check
for
system
firmware
updates.
Apply
the
update
if
available.
3.
Contact
your
next
level
of
support
for
assistance.
20E0
0001
Privileged-access
password
entry
error.
The
password
has
been
entered
incorrectly.
Retry
installing
the
password.
20E0
0004
Battery
drained
or
needs
replacement
1.
Replace
battery.
Location:
U0.1-P1-X1-V3
2.
If
problem
persists,
replace
the
service
processor
card
Location:
U0.1-P1-X1
Chapter
5.
Error
Code
to
FRU
Index
147
Summary of Contents for 9114-275 - IntelliStation POWER 275
Page 1: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 2: ......
Page 3: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 14: ...xii IntelliStation POWER 9114 Model 275 Service Guide ...
Page 16: ...xiv IntelliStation POWER 9114 Model 275 Service Guide ...
Page 50: ...32 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 58: ...40 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 81: ...Yes Go to Step 1321 16 on page 64 Chapter 3 Maintenance Analysis Procedures MAPs 63 ...
Page 210: ...192 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 246: ...228 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 320: ...System Parts 302 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 330: ...312 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 332: ...314 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 336: ...318 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 340: ...322 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 375: ......