![IBM 9114-275 - IntelliStation POWER 275 Service Manual Download Page 157](http://html.mh-extra.com/html/ibm/9114-275-intellistation-power-275/9114-275-intellistation-power-275_service-manual_606733157.webp)
SPCN
Error
Codes
Attention:
If
a
power
supply
or
fan
is
hot-swapped,
wait
five
minutes,
then
recheck
the
operating
system
error
log.
If
the
system
has
to
be
shut
down
to
replace
a
power
supply
or
fan,
reboot
the
system,
wait
five
minutes
after
the
operating
system
login
prompt
appears,
then
recheck
the
operating
system
error
log.
If
the
detailed
information
for
the
most
recent
error
with
the
same
identifier
indicates
that
the
original
problem
has
not
been
fixed
by
performing
the
first
action
in
the
action
column,
continue
with
the
next
action
in
the
action
column.
Attention:
If
you
replace
FRUs
or
perform
an
action
and
the
problem
is
still
not
corrected,
go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
87
unless
otherwise
indicated
in
the
tables.
If
you
replace
FRUs
and
the
problem
is
corrected,
go
to
″
MAP
0410:
Repair
Checkout
″
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems
.
Table
4.
SPCN
Error
Codes
for
the
System
Unit
Error
Code
Description
Action/
Possible
Failing
FRU
1011
00AC
AC
loss
Informational
message
1011
00EF
Emergency
power
off
Informational
message
1011
1510
Power
supply
1
AC
fault
1.
Check
input
power
to
the
power
supply.
2.
System
drawer
power
supply
1
Location:
U0.1-V1
1011
1511
Power
supply
1
power
fault
System
drawer
power
supply
1
Location:
U0.1-V1
1011
1512
Power
supply
1
non-power
fault
System
drawer
power
supply
1
Location:
U0.1-V1
1011
1513
Domain
fault
allocated
to
power
supply
1
System
drawer
power
supply
1
Location:
U0.1-V1
1011
1514
Power
supply
1
fan
fault
System
drawer
power
supply
1
Location:
U0.1-V1
1011
1520
Power
supply
2
AC
fault
1.
Check
input
power
to
the
power
supply.
2.
System
drawer
power
supply
2
Location:
U0.1-V2
1011
1521
Power
supply
2
power
fault
System
drawer
power
supply
2
Location:
U0.1-V2
1011
1522
Power
supply
2
non-power
fault
System
drawer
power
supply
2
Location:
U0.1-V2
1011
1523
Domain
fault
allocated
to
power
supply
2
System
drawer
power
supply
2
Location:
U0.1-V2
1011
1524
Power
supply
2
fan
fault
System
drawer
power
supply
2
Location:
U0.1-V2
1011
1B0A
+12/-12V
load
fault
Go
to
“MAP
1520:
Power”
on
page
76.
1011
1B0B
1.8V
load
fault
Go
to
“MAP
1520:
Power”
on
page
76.
1011
1B0C
3.3/1.5V
load
fault
Go
to
“MAP
1520:
Power”
on
page
76.
1011
1B0D
2.5V
load
fault
Go
to
“MAP
1520:
Power”
on
page
76.
1011
1B0E
+5V
load
fault
Go
to
“MAP
1520:
Power”
on
page
76.
1011
1B0F
1.5/1.2V
load
fault
Go
to
“MAP
1520:
Power”
on
page
76.
1011
1F01
TMS
limit
reached
-
Log
Only
Informational
message
Chapter
5.
Error
Code
to
FRU
Index
139
Summary of Contents for 9114-275 - IntelliStation POWER 275
Page 1: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 2: ......
Page 3: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 14: ...xii IntelliStation POWER 9114 Model 275 Service Guide ...
Page 16: ...xiv IntelliStation POWER 9114 Model 275 Service Guide ...
Page 50: ...32 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 58: ...40 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 81: ...Yes Go to Step 1321 16 on page 64 Chapter 3 Maintenance Analysis Procedures MAPs 63 ...
Page 210: ...192 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 246: ...228 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 320: ...System Parts 302 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 330: ...312 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 332: ...314 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 336: ...318 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 340: ...322 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 375: ......