Service
Processor
Error
Codes
Attention:
Follow
the
procedure
defined
in
the
“Checkpoint
and
Error
Code
Index”
on
page
134.
If
you
replace
FRUs
or
perform
an
action
and
the
problem
is
still
not
corrected,
go
to
“MAP
1548:
System
Processor
Problem
Isolation”
on
page
90
unless
otherwise
indicated
in
the
tables.
If
you
replace
FRUs
and
the
problem
is
corrected,
go
to
″
MAP
0410:
Repair
Checkout
″
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems
.
Table
6.
Service
Processor
Error
Codes.
Error
Code
Description
Action/
Possible
Failing
FRU
406x
0002
System
unit
backplane
fault
System
unit
backplane
Location:
U0.1-P1
406x
0003
Scan
interface
basic
assurance
tests
detected
processor
fault
System
unit
backplane
Location:
U0.1-P1
406x
000E
Processor
capacity
card
Operator
panel
Location:
U0.1-L1
406x
0010
Memory
DIMM
fault
Memory
DIMM
Location:
U0.1-P1-M5
406x
0011
Memory
DIMM
fault
Memory
DIMM
Location:
U0.1-P1-M7
406x
0012
Memory
DIMM
fault
Memory
DIMM
Location:
U0.1-P1-M4
406x
0013
Memory
DIMM
fault
Memory
DIMM
Location:
U0.1-P1-M2
406x
0014
Memory
DIMM
fault
Memory
DIMM
Location:
U0.1-P1-M6
406x
0015
Memory
DIMM
fault
Memory
DIMM
Location:
U0.1-P1-M8
406x
0016
Memory
DIMM
fault
Memory
DIMM
Location:
U0.1-P1-M3
406x
0017
Memory
DIMM
fault
Memory
DIMM
Location:
U0.1-P1-M1
406x
00B7
Insufficient
hardware
resources
were
detected
to
continue
IPL
of
the
system
after
processor
sub
system
testing
and
initialization
was
completed.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
87
406x
00D1
Informational
message
Informational
message
406x
0100
Memory
quad
A
failure
Go
to
“MAP
1240:
Memory
Problem
Resolution”
on
page
55
406x
0101
Memory
quad
B
failure
Go
to
“MAP
1240:
Memory
Problem
Resolution”
on
page
55
Chapter
5.
Error
Code
to
FRU
Index
163
Summary of Contents for 9114-275 - IntelliStation POWER 275
Page 1: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 2: ......
Page 3: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 14: ...xii IntelliStation POWER 9114 Model 275 Service Guide ...
Page 16: ...xiv IntelliStation POWER 9114 Model 275 Service Guide ...
Page 50: ...32 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 58: ...40 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 81: ...Yes Go to Step 1321 16 on page 64 Chapter 3 Maintenance Analysis Procedures MAPs 63 ...
Page 210: ...192 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 246: ...228 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 320: ...System Parts 302 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 330: ...312 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 332: ...314 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 336: ...318 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 340: ...322 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 375: ......