Table
5.
Firmware
Error
Codes.
(continued)
Error
Code
Description
Action/
Possible
Failing
FRU
1.
Power
off
the
system.
See
“Removing
a
Non-Hot-Pluggable
PCI
Adapter”
on
page
253
and
“Replacing
or
Installing
a
Non-Hot-Pluggable
PCI
Adapter”
on
page
255
for
instructions
on
reseating
the
card.
If
reseating
the
adapter
fixes
the
problem,
go
to
″
MAP
410,
Repair
Checkout
″
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems
manual.
Attention:
Before
moving
the
adapter
to
another
slot,
verify
with
the
customer
or
system
administrator
that
the
slot
that
the
adapter
is
being
moved
to
is
in
the
partition
in
which
the
adapter
presently
resides.
2.
Is
there
an
empty
slot
available
into
which
the
adapter
could
be
plugged?
YES
Move
the
adapter
to
another
slot
behind
a
different
PCI
bridge.
The
“System
Logic
Flow”
on
page
18
identifies
the
PCI
bridges
and
the
associated
slots.
See
“Removing
a
Non-Hot-Pluggable
PCI
Adapter”
on
page
253
when
removing
the
adapter,
and
“Replacing
or
Installing
a
Non-Hot-Pluggable
PCI
Adapter”
on
page
255
when
installing
the
card
in
the
new
slot.
If
the
card
is
successfully
reconfigured
in
the
new
slot
(behind
a
different
PCI
bridge),
the
slot
in
which
the
card
was
originally
plugged
is
bad.
Replace
service
processor
in
which
the
card
was
installed,
location:
U0.1-P1.
If
the
adapter
does
not
reconfigure
successfully
in
the
new
slot,
replace
the
adapter.
NO
Replace
the
adapter.
If
the
problem
is
not
resolved,
replace
system
backplane
in
which
the
card
was
installed,
location:
U0.1-P1.
3.
Go
to
“MAP
1548:
System
Processor
Problem
Isolation”
on
page
90.
If
the
location
code
does
not
identify
a
slot
or
PCI
adapter,
or
no
location
code
is
specified,
go
to
“MAP
1548:
System
Processor
Problem
Isolation”
on
page
90.
2602
0011
Description:
PCI
probe
error,
bridge
is
not
usable
Action:
If
the
location
code
identifies
a
slot:
1.
Check
the
cabling
to
the
adapter,
in
particular,
the
adapters
that
have
serial
ports.
Serial
ports
may
require
null
modems
or
special
cabling
configurations
to
avoid
connecting
driver
outputs
together.
This
may
create
a
PCI
slot
power
problem
and
force
the
adapter
to
be
deconfigured.
Attention:
Before
moving
the
adapter
to
another
slot,
verify
with
the
customer
or
system
administrator
that
the
slot
that
the
adapter
is
being
moved
to
is
available
to
the
partition
in
which
the
adapter
presently
resides.
2.
Move
adapter
to
another
slot
(behind
a
different
PCI
bus).
3.
Check
for
available
firmware
updates
for
adapter.
Apply
update
if
available.
4.
Replace
the
adapter.
5.
Check
for
system
firmware
updates.
Apply
update
if
available.
6.
If
the
card
is
in
the
system
drawer,
replace
the
system
backplane,
location:
U0.1-P1.
If
the
card
is
in
an
I/O
subsystem,
replace
the
I/O
backplane
that
contains
the
slot
in
which
the
adapter
was
originally
installed,
location:
U0.dd-P1.
2602
0012
Description:
PCI
device
run-time
error,
bridge
in
freeze
state
Action:
If
the
location
code
identifies
a
slot:
1.
Check
the
cabling
to
the
adapter.
In
particular,
the
adapters
that
have
serial
ports.
Serial
ports
may
require
null
modems
or
special
cabling
configurations
to
avoid
connecting
driver
outputs
together.
This
may
create
a
PCI
slot
power
problem
and
force
the
adapter
to
be
deconfigured.
2.
Move
adapter
to
another
slot
(behind
a
different
PCI
bus).
3.
Check
for
available
firmware
updates
for
adapter.
Apply
update
if
available.
4.
Replace
adapter.
5.
Check
for
system
firmware
updates.
Apply
if
update
available.
6.
If
the
card
is
in
the
system
drawer,
replace
the
system
unit
backplane,
location:
U0.1-P1.
If
the
card
is
in
an
I/O
subsystem,
replace
the
I/O
backplane
that
contains
the
slot
in
which
the
adapter
was
originally
installed,
location:
U0.dd-P1.
158
IntelliStation
POWER
9114
Model
275
Service
Guide
Summary of Contents for 9114-275 - IntelliStation POWER 275
Page 1: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 2: ......
Page 3: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 14: ...xii IntelliStation POWER 9114 Model 275 Service Guide ...
Page 16: ...xiv IntelliStation POWER 9114 Model 275 Service Guide ...
Page 50: ...32 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 58: ...40 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 81: ...Yes Go to Step 1321 16 on page 64 Chapter 3 Maintenance Analysis Procedures MAPs 63 ...
Page 210: ...192 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 246: ...228 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 320: ...System Parts 302 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 330: ...312 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 332: ...314 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 336: ...318 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 340: ...322 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 375: ......