Is
the
Please
define
the
System
Console
screen
displayed?
NO
Go
to
“Step
1548-16.”
YES
Repeat
this
step
until
all
of
the
FRUs
(adapters)
are
installed.
Go
to
″
MAP
0410:
Repair
Checkout
″
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems
.
Step
1548-16
The
last
FRU
installed
or
one
of
its
attached
devices
is
probably
defective.
1.
Make
sure
the
diagnostic
CD-ROM
is
inserted
into
the
CD-ROM
drive.
2.
Turn
off
the
power
and
remove
the
power
cords.
3.
Starting
with
the
last
installed
adapter,
disconnect
one
attached
device
and
cable.
4.
Plug
in
the
power
cords
and
wait
for
the
OK
prompt
to
display
on
the
operator
panel
display.
5.
Turn
on
the
power.
6.
If
the
Console
Selection
screen
is
displayed,
choose
the
system
console.
7.
After
the
word
keyboard
displays,
press
the
number
5
key
on
either
the
directly
attached
keyboard
or
on
an
ASCII
terminal
keyboard.
8.
Enter
the
appropriate
password
if
you
are
prompted
to
do
so.
Is
the
Please
define
the
System
Console
screen
displayed?
NO
Repeat
this
step
until
the
defective
device
or
cable
is
identified
or
all
devices
and
cables
have
been
disconnected.
If
all
the
devices
and
cables
have
been
removed,
then
one
of
the
FRUs
remaining
in
the
system
unit
is
defective.
To
test
each
FRU,
exchange
the
FRUs
in
the
following
order:
1.
Adapter
(last
one
installed)
2.
CEC
backplane
(see
notes
on
page
41)
If
the
symptom
did
not
change
and
all
the
FRUs
have
been
exchanged,
call
service
support
for
assistance.
If
the
symptom
has
changed,
check
for
loose
cards,
cables,
and
obvious
problems.
If
you
do
not
find
a
problem,
go
to
the
“Quick
Entry
MAP”
on
page
43
and
follow
the
instructions
for
the
new
symptom.
YES
The
last
device
or
cable
that
you
disconnected
is
defective.
Exchange
the
defective
device
or
cable.
Go
to
″
MAP
0410:
Repair
Checkout
″
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems
.
98
IntelliStation
POWER
9114
Model
275
Service
Guide
Summary of Contents for 9114-275 - IntelliStation POWER 275
Page 1: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 2: ......
Page 3: ...IntelliStation POWER 9114 Model 275 Service Guide SA38 0636 00 ...
Page 14: ...xii IntelliStation POWER 9114 Model 275 Service Guide ...
Page 16: ...xiv IntelliStation POWER 9114 Model 275 Service Guide ...
Page 50: ...32 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 58: ...40 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 81: ...Yes Go to Step 1321 16 on page 64 Chapter 3 Maintenance Analysis Procedures MAPs 63 ...
Page 210: ...192 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 246: ...228 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 320: ...System Parts 302 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 330: ...312 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 332: ...314 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 336: ...318 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 340: ...322 IntelliStation POWER 9114 Model 275 Service Guide ...
Page 375: ......