70
Part 1 Specification
I/O Signal List
Signal type
Bit
Symbol
Description
Details
b15-b7
-
Cannot be used.
-
b6
ST6
Start position command 6
b5
ST5
Start position command 5
b4
ST4
Start position command 4
b3
ST3
Start position command 3
b2
ST2
Start position command 2
b1
ST1
Start position command 1
Command
position number
b0
ST0
Start position command 0
3.8.2 (20)
b15
BKRL
Forced brake release
3.8.2 (19)
b14-b5
-
Cannot be used.
-
b4
SON
Servo ON command
3.8.2 (5)
b3 RES
Reset
command
3.8.2
(4)
b2 STP
Pause command
3.8.2 (2)
3.8.2 (10)
b1
HOME
Home return command
3.8.2 (6)
PLC ou
tp
ut
Control signal
b0
-
Cannot be used.
-
b15-b7
-
Cannot be used.
-
b6
PE6
Current position number signal 6
b5
PE5
Current position number signal 5
b4
PE4
Current position number signal 4
b3
PE3
Current position number signal 3
b2
PE2
Current position number signal 2
b1
PE1
Current position number signal 1
Completed
position number
b0
PE0
Current position number signal 0
3.8.2 (22)
b15
EMGS
Emergency stop mode
3.8.2 (2)
b14-b13
-
Cannot be used.
-
b12
ZONE1
Zone output 1 monitor
3.8.2 (13)
b11
PZONE
Position zone output monitor
3.8.2 (13)
b10-b5
-
Cannot be used.
-
b4
SV
Ready (servo ON)
3.8.2 (5)
b3 ALM
Alarm
present
3.8.2
(3)
b2
-
Cannot be used.
-
b1
HEND
Home return complete
3.8.2 (6)
PL
C
Inp
u
t
Status signal
b0
PEND
Position complete
3.8.2 (9)