143
Part 1 Specification
Teaching Mode Command (MODE)
The controller will switch to the teaching mode when the MODE signal turns “1.”
z
Query
Field name
RTU mode data
(8 bits)
Data length
(bytes)
Remarks
Header None
-
Slave address
3F H
1
Fixed.
Function code
06 H
1
Starting address
(upper)
F6 H
Starting address
(lower)
0B H
2
Address of the control signal register of axis (0)
New data (data written) (upper)
04 H
New data (data written) (lower)
10 H
2
The MODE and SON signals are “1.”
Error check
(CRC)
16 bits
2
Based on calculation result
Trailer None
-
Total bytes
8
z
Response
If the data has been changed (written) successfully, the response is the same as the query.
z
Actual Example
Sent Query:
3F06F60B0410CC52
Received Response: 3F06F60B0410CC52
Summary of Contents for RoboNet
Page 1: ...Operation Manual Forth Edition ROBONET ...
Page 257: ...237 Part 2 Startup Chapter X Installed face down X Installed face up ...
Page 354: ...334 ...
Page 395: ...375 ...
Page 396: ...376 ...
Page 397: ...377 ...