134
Part 1 Specification
Home Return Command (HOME)
z
Query
Field name
RTU mode data
(8 bits)
Data length
(bytes)
Remarks
Header None
-
Slave address
3F H
1
Fixed.
Function code
06 H
1
Starting address
(upper)
F6 H
Starting address
(lower)
0B H
2
Address of the control signal register of axis (0)
New data (data written) (upper)
00 H
New data (data written) (lower)
12H
2
Error check
(CRC)
16 bits
2
Based on calculation result
Trailer None
-
Total bytes
8
z
Response
If the data has been changed (written) successfully, the response is the same as the query.
z
Actual Example
Sent Query:
3F06F60B00124F53
Received Response: 3F06F60B00124F53
Be sure to turn on the servo before executing the home return command.