4-6
OPERATING FLOW
Battery Battery relay Circuit breaker [CN-60] Master switch [CS-74A] I/conn [CN-231 (2)]
Fuse box [No.1] I/conn [CN-36-4 (2)] DCU relay [CR-101 (30)]
Fuse box [No.2] I/conn [CN-36-1 (7)] Master switch [CS-74B] l/conn [CN-5 (36)]
Start switch [CS-2A (1)]
RMS [CN-125A (1)]
GPS connection [CN-125 (1)]
Power relay [CR-35 (30)]
Fuse box [No.3] I/conn [CN-36-1 (8)] I/conn [CN-5 (59)]
I/conn [CN-10 (3)] Room lamp [CL-1 (2)] Door switch [CS-1]
Radio & USB player [CN-27 (8)]
Hour meter [CN-48 (1)]
Fuse box [No.4] l/conn [CN-36-2 (2)] l/conn [CN-11 (5)] AC & Heater controller (3)
Blower relay (3)
Fuse box [No.5] I/conn [CN-36-4 (1)] I/conn [CN-3 (1, 6, 11)]
Engine ECM [CN 93-J1 (84, 85, 86)]
DEF/AdBlue® purging lamp [CL-40 (1)]
Fuse box [No.6] l/conn [CN-36-1 (11)] I/conn [CN - 5 (18)] I/conn [CN -17 (5)]
Wiper motor controller [CN-141 (7)]
Wiper motor [CN-21 (4)]
Fuse box [No.7] I/conn [CN-36-1 (12)] I/conn [CN-5 (11)] Cluster [CN -56A (1)]
Fuse box [No.8] I/conn [CN-36-1 (13)] MCU [CN-51 (1)]
MCU [CN-53 (1)]
#
侍
I/conn : Intermediate connector
CHECK POINT
侍#
GND : Ground
1)
2)
1. POWER CIRCUIT
The negative terminal of battery is grounded to the machine chassis.
When the start switch is in the OFF position, the current flows from the positive battery terminal as
shown below.
Engine
Start switch
Check point
Voltage
OFF
OFF
刮
- GND (battery 1EA)
刯
- GND (battery 2EA)
到
- GND (battery relay)
刱
- GND (circuit breaker)
10~12.5V
20~25V
20~25V
20~25V
Summary of Contents for HX145 LCR
Page 11: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Page 204: ...4 5 MEMORANDUM HYUNDAI HEAVY INDUSTRIES CO LTD CONSTRUCTION EQUIPMENT DIV...
Page 627: ...8 155 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...