5-23
DTC
Diagnostic Criteria
Application
HCESPN FMI
G
C
W
140
5
(Detection)
(When Pump EPPR Current is more than 10 mA)
10 seconds continuous, Pump EPPR drive current < 0 mA
(Cancellation)
(When Pump EPPR Current is more than 10 mA)
3 seconds continuous, Pump EPPR drive current
≥
10 mA
侑
6
(Detection)
10 seconds continuous, Pump EPPR drive current > 1.0A
(Cancellation)
3 seconds continuous, Pump EPPR drive current
≤
1.0 A
侑
(Results / Symptoms)
1. Control Function – Pump horse power setting specification difference
(Fuel efficiency/speed specification failure)
(Checking list)
1. CN-75 (#2) – CN-52 (#9) Checking Open/Short
2. CN-75 (#1) – CN-52 (#10) Checking Open/Short
141
5
(Model Parameter) mounting Boom Priority EPPR
(Detection)
(When Boom Priority EPPR Current is more than 10 mA)
10 seconds continuous, Boom Priority EPPR drive current < 0 mA
(Cancellation)
(When Boom Priority EPPR Current is more than 10 mA)
3 seconds continuous, Boom Priority EPPR drive current
≥
10 mA
侑
6
(Detection)
10 seconds continuous, Boom Priority EPPR drive current > 1.0 A
(Cancellation)
3 seconds continuous, Boom Priority EPPR drive current
≤
1.0 A
侑
(Results / Symptoms)
1. Control Function – Boom first control operation failure
(Checking list)
1. CN-133 (#2) – CN-52 (#34) Checking Open/Short
2. CN-133 (#1) – CN-52 (#35) Checking Open/Short
G : General C : Crawler Type W : Wheel Type
侍#
Some error codes are not applied to this machine.
Summary of Contents for HX145 LCR
Page 11: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Page 204: ...4 5 MEMORANDUM HYUNDAI HEAVY INDUSTRIES CO LTD CONSTRUCTION EQUIPMENT DIV...
Page 627: ...8 155 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Page 657: ...8 185 8 185 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...