2-33
B5
A5
Tank passage
From RCV
Bucket spool
P1 Parallel passage
Pa5
P04
Check 1
Check 2
P1 Bypass passage
Bucket
stroke limiter
145LCR2MC29
BUCKET IN OPERATION WITH BOOM UP OPERATION
BUCKET IN OPERATION WITH BOOM UP OPERATION
When combined operation, mostly same as previous page but the fluid from P1 bypass passage
is empty.
So only the fluid from P1 parallel passage is supplied to the bucket cylinder. Also, parallel
passage is installed the bucket stroke limiter for supplying the fluid from pump A2 to the
boom operation prior to the bucket operation. In case of the bucket out operation with boom
operation, operation is similar.
(3)
(3)
Summary of Contents for HX145 LCR