5-29
DTC
Diagnostic Criteria
Application
HCESPN FMI
G
C
W
181
4
(Model Parameter) mounting Reverse Cooling Fan Solenoid
(Detection)
(When Reverse Cooling Fan Solenoid is Off)
10 seconds continuous, Reverse Cooling Fan Solenoid drive unit
Measurement Voltage
≤
3.0V
(Cancellation)
(When Reverse Cooling Fan Solenoid is Off)
3 seconds continuous, Reverse Cooling Fan Solenoid drive unit
Measurement Voltage > 3.0V
侑
6
(Detection)
(When Reverse Cooling Fan Solenoid is On)
10 seconds continuous, Reverse Cooling Fan Solenoid drive current > 4.5 A
(Cancellation)
(When Reverse Cooling Fan Solenoid is On)
3 seconds continuous, Reverse Cooling Fan Solenoid drive current
≤
4.5 A
侑
(Results / Symptoms)
1. Control Function – Cooling Fan reverse control operation failure (not applicable)
188
5
(Detection)
(When Attachment Flow EPPR 1 current is equal or more than 300 mA)
10 seconds continuous, Attachment Flow EPPR drive current < 100 mA
(Cancellation)
(When Attachment Flow EPPR 1 current is equal or more than 300 mA)
3 seconds continuous, Attachment Flow EPPR drive current
≥
100 mA
侑
6
(Detection)
10 seconds continuous, Attachment Flow EPPR 1 drive current > 1.0 A
(Cancellation)
3 seconds continuous, Attachment Flow EPPR 1 drive current
≤
1.0 A
侑
(Results / Symptoms)
1. Control Function – IPC operation failure, Option attachment flow control operation failure
(Checking list)
1. CN-242 (#2) – CN-52 (#39) Checking Open/Short
2. CN-242 (#1) – CN-52 (#40) Checking Open/Short
G : General C : Crawler Type W : Wheel Type
侍#
Some error codes are not applied to this machine.
Summary of Contents for HX145 LCR
Page 11: ...SECTION 1 GENERAL SECTION 1 GENERAL Group 1 Safety Hints 1 1 Group 2 Specifications 1 10...
Page 204: ...4 5 MEMORANDUM HYUNDAI HEAVY INDUSTRIES CO LTD CONSTRUCTION EQUIPMENT DIV...
Page 627: ...8 155 125LCR8TM30 Turn casing 1 upside down and remove oil seal 3 using jig 29...
Page 657: ...8 185 8 185 Remove lock nut 22 and then boot 23 14 36078RL14 2507ARL10...