Remove O-ring (19) from casing.
Use a magnet to separate swash plate (7) from
casing.
Sliding surface should be carefully treated to
avoid scratches and damage.
(17)
(18)
※
Disassemble shaft (3) and cylinderical roller
bearing (5).
Do not remove cylinderical roller bearing (5)
unless malfunction is detected, since it is
mounted by shrink fit.
(19)
※
Turn casing (1) upside down and remove oil seal
(2) using jig.