6-46
TEST PROCEDURE
TEST PROCEDURE
Test 7
Test 7 : Check voltage at CN-52 (38) and
ground.
Prepare 1 piece of thin sharp pin, steel or
copper.
Inser t prepared pin to rear side of
connectors : One pin to (38) of CN-52.
Starting switch ON.
Check voltage as figure.
Test 8
Test 8 : Check voltage at CN-52 (37) and
ground.
Prepare 1 piece of thin sharp pin, steel or
copper
Inser t prepared pin to rear side of
connectors : One pin to (37) of CN-52.
Starting switch ON.
Check voltage as figure.
MCU
CN-51
CN-52
Female
CN-52
1
2
3
4
5
6
7
8
9
10
31
32
33
34
36
37
38
39
40
11
21
20
30
Multimeter
GROUND
1
2
3
4
5
6
7
8
9
10
31
32
33
34
36
37
38
39
40
11
21
20
30
Multimeter
GROUND
35
CN-52
Female
37
38
PIN
(1)
(1)
(2)
(2)
①
②
③
④
①
②
③
④
2)
2)
SPEC : Actuator operating : 1~5 V