Figure 7-28
Connecting one SUD to one SUC
NOTE
l
A 4 U SUD with SAS ports is used as an example in
configure a 2 U SUD with SAS ports, see
, and
. To configure
a 4 U SUD with Fibre Channel ports, utilize ports 1, 2, 3, and 4 in order on the 4 Gbit/s Fibre Channel
interface module of the SUC. For details on the connection network, see
,
l
The numbers following SUDs, as shown in
, and
, are enclosure
IDs of SUDs. The enclosure ID of the first SUD positively connected by port P 0 on the SUC's
controller A is automatically identified as 1.
To connect two SUDs to one SUC, attach ports EXP 0 on SUC's controllers A and B to ports
PRI on SUD's disk modules A and B. One expansion loop is generated. Then attach ports EXP
1 on SUC's controllers A and B to ports PRI on another SUD's disk modules A and B. Another
expansion loop is generated, as shown in
OceanStor N8500 Clustered NAS Storage System
Installation Guide (for T Series V100R005)
7 N8500 Installation (with S5600T, S5800T or S6800T
Storage System as the Storage Unit)
Issue 02 (2015-09-22)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
203