Gx
Series
EN - 110
Test 3
C
heck states of the EVSE system
The purpose of this test (consisting of 6 steps) is to check all the internal states of the
EVSE system in accordance with the prescriptions of the reference standards by
performing simulations with the EV-TEST100 accessory connected. The situations
considered are the followed:
State
Select.
CP
Select.
PP
Select.
FAULT
Ventilation
Parameters
checked
Limits
Outcome
OK
Outcome
NO OK
A A NC OK
,
VL1N
≤
10V
>10V
VL1-PE
≤
10V
>10V
VN-PE
≤
10V
>10V
VCP (peak)
12V±0.6V
-
Frequency DC
(0Hz)
-
Charge current
≤
0A
-
B B
Nominal
current
OK
,
Check plug
locked
plug
unlocked
plug
B B
Nominal
current
OK
,
VL1N
≤
10V
>10V
VL1-PE
≤
10V
>10V
VN-PE
≤
10V
>10V
VCP (peak)
9V±0.6V
-
Frequency DC
(0Hz)
-
Charge current
≤
0A
-
C C
Nominal
current
OK
VL1N Vnom±10%
external
interval
VL1-PE Vnom±10%
VN-PE
≤
25V
>25V
VCP (peak)
6V±0.53V
-
Frequency 1kHz±0.5%
-
Charge current
calculated
-
D D
Nominal
current
OK
VL1N Vnom±10%
external
interval
VL1-PE Vnom±10%
VN-PE
≤
25V
>25V
VCP (peak)
3V±0.6V
-
Frequency 1kHz±0.5%
-
Charge current
calculated
-
FPE C
Nominal
current
PE
,
VL1N
≤
10V
>10V
VL1-PE
≤
10V
>10V
VN-PE
≤
10V
>10V
VCP (peak)
≤
11V
-
Frequency DC
(0Hz)
-
Charge current
≤
0A
-
FE C
Nominal
current
E
,
VL1N
≤
10V
>10V
VL1-PE
≤
10V
>10V
VN-PE
≤
10V
>10V
VCP (peak)
≤
11V
-
Frequency DC
(0Hz)
-
Charge current
≤
0A
-
Table 4:
List of situations considered in states check
=
Test considered positive even if parameter is out of limits