![background image](http://html.mh-extra.com/html/ht/combig2/combig2_user-manual_2178066113.webp)
Gx
Series
EN - 112
24
Act on the three adapter selectors by setting the
following positions as shown by the instrument with
flashing red/blue indications:
PP State
13A,20A,32A or 63A
CP State
B
Fault
OK
Try to remove the connection plug of the EV-TEST100
adapter in order to check if the EVSE system
performs
the correct locking
as indicated in the screen to the
side
Press the icon
if the operation is successful and
continue with the next test (point 26) or press the icon
to
end the test sequence
NOTE: some EVSE stations could not have the
mechanical locking system. In this case, to
continue with the tests, select the icon
25 Repeat the sequence again after restoring normal
operation of the EVSE system
26
Press the icon
to activate the
test on B state
. The
following screen is shown on the display
P
ress the icon
to exit the test and return to the
initial screen
27
The result of the measurement is shown in the screen
to the side
. The symbol
indicates the correct result
of the measurement.
The symbol
also indicates a
positive result of the measurement but with values
outside the limits present in the Table 4
.
Press the
SAVE
key or touch the icon
for the
partial saving of the test and
continue with the next test
(point 30 to check C status or point 34 to check D
status
Press again the
GO/STOP
key to repeat the test