Gx
Series
EN - 113
28
If the test fails, the screen like the one on the side is
shown on the display. The incorrect value of the
parameter is shown in red and the symbol
indicates
the non-ok result of the measurement
.
Press again the
GO/STOP
key to repeat the test
Press the
SAVE
key or touch the icon
for the
partial saving of the test and to
end the test sequence
.
The instrument shows the message shown in the
followed screen for a few seconds
29 Repeat the sequence again if necessary
30
In case of EVSE system in unventilated
environment
, act on the three selector switches of the
adapter by setting the followed positions as shown by
the instrument with flashing red / blue indications
PP State
13A,20A,32A or 63A
CP State
C
Fault
OK
Press the icon
to activate the
test on C state
. The
following screen is shown on the display
Press the icon
to exit the test and return to the
initial screen
31
The result of the measurement is shown in the screen
to the side
. The symbol
indicates the correct result
of the measurement.
The symbol
also indicates a
positive result of the measurement but with values
outside the limits present in the Table 4.
Press again the
GO/STOP
key to repeat the test
.
Press the
SAVE
key or touch the icon
for the
partial saving of the test and
continue with the next test
(point 38)
Press again the
GO/STOP
key to repeat the test