Use press plate to lock mating receptacles into interposers.
Press force should not exceed 500N for 300 pos, 400N for 200 pos, and 300N for
100 pos.
Example:
One 200-signal connector: do not exceed 400N insertion force
Two 200-signal connectors (400 signals): do not exceed 800N insertion force.
Install nuts on spacer studs. Tighten to specified torque.