IT3/IT5
Connector System
D
ESIGN
N
OTES
Document Number:
ETAD-F0458
Revision 3.10
Page
20
of
73
Recommended Spacer Location
10 -
50mm
10 -
50mm
Non plated through hole
Φ
3.5
3.4 Clearance between Connectors
Parallel Mounting
If
overlap distance is less than half
the length of the connector:
Socket Combinati ons
Connector Minimum Pitch (mm)
Connector Maximum Pitch (mm)
All combi nations
24.10
209.20
If
overlap distance is more than half
the length of the connector:
Interposer Outline
C
o
n
n
e
c
to
r
P
it
c
h
Two spacers located diagonally are
minimally required. Some applications
may require four spacers.
Spacers should be located 10 – 50 mm
from the corners of the receptacles to
prevent excessive mechanical loading
on the interconnections.
If assembly will be subjected to
vibration, spacers should be located to
prevent resonance, and additional
spacers may be required.
Recommended Spacer Location