Appendix B Parameters
Shenzhen Hpmont Technology Co., Ltd.
-84-
HD3Z Series User Manual V1.2
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F02.06
Compensation for full
speed tracking
0.000 - 2.000Hz
0.000Hz
0.001Hz
○
F02.13
Stop modes at speed
control
0: Decelerate to stop
1: Coast to stop
2: Decelerate to stop + DC brake
0
1
×
F02.14
Stop DWELL frequency
setting
0.00Hz - Upper limit frequency
0.00Hz
0.01Hz
×
F02.15
Stop DWELL frequency
retention time
0.00 - 10.00s
0.00s
0.01s
×
F02.16
Starting frequency of stop
DC brake
0.00 - 50.00Hz
0.50Hz
0.01Hz
×
F02.17
Waiting time of stop DC
brake
0.00 - 60.00s
0.00s
0.01s
×
F02.18
Stop DC brake time
0.00 - 60.00s
0.50s
0.01s
×
F02.19
Jog control mode
Unit:
0: Can not jog the start and stop
function
1: Can jog the start and stop
function
Ten:
0: Terminal jog is not preferred
1: Terminal jog is preferred
10
1
×
F02.21
DC brake starting time 2
0 - 6000s
0s
1s
×
F03: Acc. / Dec. Parameter (on pages 34 - 35)
F03.00
Acc. / Dec. modes
selection
Unit: Acc. / Dec. modes selection
0: Linear Acc. / Dec.
1: S curve Acc. / Dec.
Ten: Reference frequency for Acc. /
Dec. time
0: Max frequency (F00.06)
1: Setting frequency
00
1
○
F03.01
Acc. time 1
0.1 - 6000.0s
Depend on
model
0.1s
○
F03.02
Dec. time 1
0.1 - 6000.0s
0.1s
○
F03.03
Acc. time 2
0.1 - 6000.0s
0.1s
○
F03.04
Dec. time 1
0.1 - 6000.0s
0.1s
○
F03.05
Acc. time 3
0.1 - 6000.0s
0.1s
○
F03.06
Dec. time 1
0.1 - 6000.0s
0.1s
○
F03.07
Acc. time 4
0.1 - 6000.0s
0.1s
○
F03.08
Dec. time 1
0.1 - 6000.0s
0.1s
○
F03.09
Switching frequency of
Acc. time 1 and 2
0.00Hz - Upper limit frequency
0.00Hz
0.01Hz
○