Appendix B Parameters
Shenzhen Hpmont Technology Co., Ltd.
-82-
HD3Z Series User Manual V1.2
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F00.14
Frequency setting control
Ten: Control selection of frequency
setting at stop
0: Do not restore to F00.13 at stop
1: Restore to F00.13 at stop
Hundred: Save selection of
communication setting frequency
0: Do not save when power is off
1: Save to F00.13 when power is off
Thousand: Save selection of
frequency setting when switching
frequency channel
0: Do no save
1: Save
1001
1
○
F00.15
Jog running frequency
digital setting 1
0.00Hz - Upper limit frequency
5.00Hz
0.01Hz
○
F00.16
Interval of jog running
0.0 - 100.0s
0.0s
0.1s
×
F00.17
Running direction
0: The same as running command
1: Opposite to running command
0
1
×
F00.18
Reverse
0: Permitted
1: Prohibitted
0
1
×
F00.19
Dead time of direction
switch
0.0 - 3600.0s
0.0s
0.1s
×
F00.21
Dormant function
0: Disabled
1: Enable
0
1
×
F00.22
Dormancy wake up time
0.0 - 6000.0s
1.0s
0.1s
○
F00.24
Dormancy delay time
0.0 - 6000.0s
1.0s
0.1s
○
F00.25
Dormancy frequency
0.00Hz - Upper limit frequency
0.00Hz
0.01Hz
○
F00.26
Action selection of HD3Z
at zero-speed
Unit: Action selection of zero-speed
under V/f control
0: Do not process
1: HD3Z does not output
2: HD3Z runs at DC brake
Ten: Unused
11
1
×
F00.27
Command channel
binding frequency
channel
Unit: Keypad binds to frequency
channel
Ten: Terminal binds to frequency
channel
Hundred: SCI binds to frequency
channel
0: No binding
1: Keypad digital setting
2: Terminal digital setting
3: SCI setting
5: Terminal pulse setting
000
1
×