Shenzhen Hpmont Technology Co., Ltd.
Chapter 6 Function Introduction
HD3Z Series User Manual V1.2
-43-
6.2.12
F15: Digital I/O Terminal Parameters
Ref. Code
Function Description
Setting Range [Default]
F15.00
DI1 function
0 - 91 [2]
F15.01
DI2 function
0 - 91 [3]
F15.02
DI3 function
0 - 91 [0]
F15.03
DI4 function
0 - 91 [0]
F15.04
DI5 function
0 - 91 [0]
F15.05
DI6 function
0 - 91 [0]
0: Unused. It disables the terminal function. HD3Z ignores any signal input via this terminal.
•
The unused terminal is recommended to be set as 0 to avoid wrong connection or action.
1: Inverter enabled.
•
When enabled, HD3Z is enabled to run;
•
When disabled, HD3Z is disabled to run and will be in auto stop status.
•
If no terminal selects this function, it defaults that HD3Z is enabled.
2,3: FWD / REV.
•
FWD / REV is valid only in terminal control mode.
•
Refer to F15.16.
4: Three-wire running mode.
•
Refer to F15.16.
5 - 7,87: Frequency setting channel selection 1 - 4.
•
Achieve 2n frequency setting channel via terminals logic combination (n ≤ 4), as follow table.
Channel 4
(No.87)
Channel 3
(No.7)
Channel 2
(No.6)
Channel 1
(No.5)
Setting channel
0
0
0
0
Not change
0
0
0
1
Keypad digital
0
0
1
0
Terminal
0
0
1
1
Communication digital
0
1
0
0
Analogue
0
1
0
1
High speed pulse
0
1
1
X
Not change
1
0
0
0
Keypad digital
1
0
0
1
Terminal digital
1
0
1
0
Communication digital
1
0
1
1
AI1
1
1
0
0
AI2
123
8: Switch to analogue.
•
When valid, frequency setting channel is switched to to analogue.
•
Priority of frequency setting channel:
Timing frequency switch > button switching function (F00.12 = 1) > Switch from frequency to
analogue (DI = 8) > Switch to normal running mode (DI = 30) > Multi-speed (DI = 13 - 16) > frequency
setting channel terminal 1 - 3 (DI = 5 - 7) > channel set by F00.10.
6