Chapter 6 Function Introduction
Shenzhen Hpmont Technology Co., Ltd.
-52-
HD3Z Series User Manual V1.2
Ref. Code
Function Description
Setting Range [Default]
F16.19
AO1 function
0 - 20 [2]
F16.20
AO2 function
0 - 20 [0]
0: Unused.
1,2: Output frequency / setting frequency (0 - max. output frequency).
3: Motor RPM (0 - max. output frequency corresponding to RPM).
4: Output current (0 - twice rated current of HD3Z).
5: Output current (0 - twice rated current of motor).
10: Output torque (0 - 3 times rated torque of motor).
11: Output torque (0 - 1.2 times rated voltage of HD3Z).
12: Bus voltage (0 - 2.2 times rated voltage of HD3Z).
13: Output power (0 - twice rated power of motor).
14: AI1 input (0 - max. AI1 after calculating).
15: AI2 input (0 - max. AI2 after calculating).
18,19: Output frequency, setting frequency (-1 - 1 times max. output frequency).
20: Setting frequency (0 - max. output frequency).
F16.22
AO1 bias
-100.0 - 100.0 [0.0%]
F16.23
AO1 gain
0.0 - 200.0 [100.0%]
User can use output gain to adjust AO1 output. Below is a figure shows curve relationship between AO and
F16.22, F16.23.
•
AO gain and bias formula: Actual output = F16.23 × value before calcu F16.22.
F16.24
AO2 bias
-100.0 - 100.0 [0.0%]
F16.25
AO2 gain
0.0 - 200.0 [100.0%]
Value after calculating (V)
100%
F16.23=100%
F16.22=0
F16.22=0
F16.23=200%
Value after calculating (V)
F16.22=0
F16.23=100%
F16.22=50%
F16.23=50%
50%
100%
0V
10V
0V
5V
10V
Value before
calculating (V)
Value before
calculating (V)