HD3Z Quick Start Guide
Note:
Some of the parameters are factory setting, user mayn't need to set them when first time using the product.
(1). Start / Stop HD3Z and set running frequency via keypad
1. Power on HD3Z. Use keypad to set below parameter.
Ref. Code
Function
Setting
Description
F00.10
Frequency setting channel selection 0 (default)
Running frequency set by keypad digital
setting
F00.11
Command setting channel selection 0 (default) Keypad runs command channel
F00.13
Running frequency digital setting
-
Running frequency, adjust according to
actual
F03.01 / F03.02 Acc. / Dec. time 1
-
Acc. / Dec. time, adjust according to actual
F08.00 - F08.04
Rated parameter of motor
-
Set according to motor nameplate
2. Press
on keypad to start HD3Z. Press
/ key to increase / decrease setting frequency.
Press
to stop HD3Z.
(2). To use terminal to start / stop HD3Z, and analogue value to set running frequency
1. DI1 is forward signal input, DI2 is reverse signal input. Below is the connection.
2. Power on HD3Z. Set function codes according to connection.
Ref. Code
Function
Setting
Description
F00.10
Select frequency setting channel
3
Set by analogue value
F00.11
Select command setting channel
1
Terminal
F03.01 / F03.02 Acc. / Dec. time 1
-
Acc. / Dec. time 1, adjust according to actual
F08.00 - F08.04
Rated parameter of motor
-
Set according to motor nameplate
F15.00
DI1 function selection
2 (default) FWD (DI FWD signal input)
F15.01
DI2 function selection
3 (default) REV (DI REV signal input)
F16.01
AI1 function selection
2 (default) Frequency setting channel (set by AI1)
3. Adjust AI1 to set running frequency.
4. Connect K1, motor will forward run. Disconnect it, motor stops running. Connect K2, motor reverse
run. Disconnect K2, motor stops running. Connect or disconnect both K1 and K2, motor stops running.
DI1
COM
DI2
AI1
+10
Fault indicating
Output indicating
signal at running
K1
K2
DO1
R1C
R1B
R1A
GND
Forward
Reverse
Analogue input