Figure 3-11 Removing and Replacing the Front Bezel
The front control panel access door is on the bezel. Opening the control panel door provides
access to the following components:
•
Power button
•
System LEDs
Replacing the Front Bezel
To replace the front bezel, hold the bezel in the mounting position and push the bezel straight
into the chassis until it snaps into place.
Front and Top Covers
CAUTION:
Do not operate the server without the front and top covers in place. Operation of
the server without the front and top covers in place makes the server susceptible to electromagnetic
interference (EMI) and overheating problems that result in system failure.
Observe all electrostatic discharge (ESD) safety precautions before attempting this procedure.
Failure to follow ESD safety precautions can result in damage to the server.
NOTE:
When the front or top cover is removed, the chassis fan units increase to high speed to
assist cooling. When the top cover is replaced at the end of the operation, the chassis fans return
to normal speed.
Removing the Front Cover
CAUTION:
Power the server off before removing the front cover. All the components that are
accessible behind the front cover are cold-swappable and require power to be off.
To remove the front cover, follow these steps:
64