![HP rp4410 Service Manual Download Page 182](http://html.mh-extra.com/html/hp/rp4410/rp4410_service-manual_164080182.webp)
NOTE:
The positive terminal of the battery is designated by the plus (+) sign. The battery
is installed with the plus (+) sign facing up.
7.
Replace the I/O baseboard assembly. See
“Replacing the I/O Baseboard Assembly” (page 177)
8.
Replace the top cover. See
“Replacing the Top Cover” (page 154)
.
9.
Reset the server time and date, and restore the iLO MP configuration settings. Proceed as
follows:
a.
Using the system console, set the system time and date using the BCH
DATE
command.
b.
Using the system console, configure the iLO MP. Incorporate settings saved before
removing the I/O baseboard assembly or set up the iLO MP as needed. (For additional
information about using the iLO MP, see the HP Integrity and HP 9000 iLO MP Operations
Guide).
Removing and Replacing PCI/PCI-X Cards
HP 9000 rp4410 and rp4440 servers can contain up to eight PCI/PCI-X cards. PCI/PCI-X cards
are located on the I/O baseboard assembly, under the top cover. Two of these cards are dedicated
to I/O functions and require that the server be powered off for card replacement. The remaining
six PCI/PCI-X cards can be hot-plugged (replaced while power is on and the system is operating).
This section describes hot-pluggable operations and PCI/PCI-X card replacement and addresses
the following topics:
•
PCI/PCI-X Configurations
Describes PCI/PCI-X capabilities and relates card functions and capabilities to specific slots.
•
Online Addition (OLA)
Installing new PCI/PCI-X expansion cards in empty slots without powering off the server.
•
Online Replacement (OLR)
Replacing a PCI/PCI-X card without powering off the server. This action requires suspending
the associated driver. The existing driver for the old card must be compatible with the new
card.
CAUTION:
A special OLR requirement for HP-UX 11i v1 (and higher) is that the card to
be replaced must be exactly the same as the removed card. This is also called like-for-like
replacement.
•
PCI/PCI-X Slot Location (Locate)
To easily locate the PCI/PCI-X slot at which to perform a hot-pluggable operation, you can
command the attention LEDs on the OLX divider and the I/O baseboard to blink and act as
visual cues to the active slot location. This operation is always initiated through a software
or web interface, and is optional to the operating system on the server.
PCI/PCI-X Configurations
PCI/PCI-X slots are numbered from 1 through 8 in the server.
182
Removing and Replacing Components
Summary of Contents for rp4410
Page 16: ...16 ...
Page 20: ...20 ...
Page 42: ...42 ...
Page 50: ...50 ...
Page 128: ...128 ...
Page 176: ...Figure 6 21 I O Baseboard Locking Lever 176 Removing and Replacing Components ...
Page 230: ...230 ...
Page 240: ...240 ...
Page 242: ...242 ...