4.
Insert the processor extender board.
NOTE:
For this example, the processors were not removed from the processor extender
board first. Also, this example shows the expected results for an rp4440 system with two
processor modules installed. HP recommends having at least one processor module installed
(Module 0), or slightly different Alert Messages can appear.
The system fans come on and stay on when you add the processor extender board and
processors. The
DF
command output appears as follows:
CRU IDs: --------
0001-Mem Extender 0002-Power Converter 0003-Power Supply 0
0004-Power Supply 1 0005-Diagnostic Panel 0006-Front Panel
0007-Disk Management 0008-Disk Backplane 0010-Processor Board
0012-Power Pod 0 0013-Power Pod 1 0032-CPU 0 PIROM
0033-CPU 1 PIROM 0036-Processor 0 RAM 0037-Processor 1
RAM
0128-DIMM0A 0136-DIMM0B 0144-DIMM0C
0152-DIMM0D 0160-DIMM1A 0168-DIMM1B
0176-DIMM1C 0184-DIMM1D 0000-Motherboard
5.
If all the installed hardware is functional, the system initiates POST. Go immediately into
the SEL Live Logs or the VFP to ensure that POST is initiated and proceeds without error
to BCH. For the rp4440 server, you do not normally see any POST forward progress messages
on the console unless you are in
SL
live mode.
6.
If POST does not start after five to ten seconds, suspect a problem with the processor extender
board or the processors mounted on it. Typical symptoms of this problem are an FRB2 hang
alert appearing in the SEL. Perform the following steps:
a.
Reduce the processors to one module in position 0 and retest.
b.
Replace the CPU module or swap the CPU module with one previously removed and
try replacing the processor extender board.
NOTE:
A dipswitch on the processor extender board determines whether it runs Itanium or
PA-RISC code. Be sure to check this switch position if you get an FRB2 hang and have
previously replaced the processor extender board as part of the troubleshooting
procedure.
For the rp4440 server, this switch (switch block S5103 lowest-most switch block when
viewed with extractor handles toward you) must be set to the right (PA-RISC).
This switch position setting is normally physically stamped on the sheet metal cover
for convenience.
7.
If you get any other error at this point, re-examine the SEL events and see if they point to
the root cause. If the SEL logs do not assist in pointing to the root cause, HP recommends
that you get the assistance of a systems expert.
Operating System Boots
If your operating system is running and you are experiencing problems, use the following online
tools to help solve your problem:
•
Support Tools Manager (STM)
•
Event Monitoring Service (EMS)
•
iLO MP
See
“Troubleshooting Using Online Support Tools” (page 135)