Powering On the Server Manually
NOTE:
If the power restore feature is set to Always On through the iLO MP
PR
command, the
server automatically powers on to the full power state.
To manually power on the server, follow these steps:
1.
Plug all the power cables into the receptacles on the rear panel of the server.
2.
To start the server, press the power button.
3.
Start the operating system.
Powering Off the Server
Power off the server using the following methods if the server is in the standby or full power
state:
•
iLO MP
PC
command
•
Power button
Powering Off the Server Using the iLO MP
To power off the server using the iLO MP, follow these steps:
1.
Gracefully shut down the operating system.
2.
Initiate a console session, and access the
MP Main Menu
.
3.
Enter
CM
to enable command mode.
4.
To use the remote power control command, enter
PC
.
5.
To power off the server, enter
OFF
.
6.
To confirm the action, enter
YES
when prompted.
IMPORTANT:
The main DC voltage is now removed from the system; however, AC voltage
for standby power is still present in the server.
7.
Unplug all power cables from the receptacles on the rear panel of the server.
Powering Off the Server Manually
To manually power off the server, follow these steps:
1.
Gracefully shut down the operating system.
2.
To power off the server, press the power button.
IMPORTANT:
The main DC voltage is now removed from the system; however, AC voltage
for standby power is still present in the server.
3.
Unplug all the power cables from the receptacles on the rear panel of the server.
Powering the Server On and Off