Chapter 4
Cable Connections
Guardian Service Processor (GSP) Overview
52
•
10/100 Base-T LAN connector for revision B GSP
•
On-board processor dedicated to GSP functions
•
Error logging and notification
•
Display of system alerts and selftest chassis codes
•
Powered by 15 VDC housekeeping power that is present when the front panel switch is off
•
Power and configuration monitoring
•
RS-232, LAN, REMOTE and WEB console access
•
Administrator and user security
•
Alphanumeric paging.
There are two revisions of rp54xx GSP: revision A (A6696A) and revision B (A6696B). Due to significant
hardware differences between the revision A and B GSP, each GSP requires it’s own firmware. Revision A
GSP firmware can only be installed in a revision A GSP and revision B GSP firmware can only be installed in
a revision B GSP. The hardware differences are necessary to incorporate the embedded web access, 10/100
Base-t LAN, and faster GSP processor.
The GSP provides four types of console access: RS-232, Remote, LAN and Web. Console information is
mirrored to all four console types. Refer to
Configure System Console
for more information.
The GSP was originally a core component of the revision A rp5400 (A5576A) and rp5450 (A5191A) servers.
Beginning with introduction of the revision B rp5400 (A5576B), rp5450 (A5191B), and rp5470 servers the
GSP became a separate, must order product (A6696A).
Revision A GSP
The revision A GSP is identified by product number A6696A and part numbers: A5191-60012, A5191-69012,
and A5191-69112.
The revision A GSP requires a “W” cable to be attached to the DB25 connector. The part number of the “W” is
A5191-63001. The “W” cable provides female DB9 connectors for CONSOLE, REMOTE and UPS. The
maximum supported baud rate for the CONSOLE and REMOTE connectors is 19200 baud and 1200 baud for
the UPS.
The paths for the CONSOLE, UPS, and REMOTE are 0/0/4/0.0, 0/0/4/0.1, and 0/0/4/0.2 respectively.
For the rev A GSP, the web console is accomplished by shipping one J3591A Secure Web Console with each
rp54xx server. The Secure Web Console can be used in place of an ASCII console to provide console access via
a web connection. If you are installing an rp54xx server that does not have an ASCII console, you may use the
Secure Web Console as the console. However, you must first configure the Secure Web Console. Refer to
Secure Web Console Installation and Configuration
for more information on SWC Installation/Configuration.
Revision B GSP
The revision B GSP is identified by product number A6696B and part numbers: A6144-60012, A6144-69012,
and A6144-69112.
The revision B GSP requires an “M” cable to be attached to the DB25 connector. The part number of the “M”
cable is A6144-63001. The “M” cable provides female DB9 connectors for CONSOLE, REMOTE, and UPS.
The maximum supported baud rate for the CONSOLE and REMOTE connectors is 38400 baud and 1200
baud for the UPS.
The paths for the CONSOLE, UPS, and REMOTE are 0/0/4/1.0, 0/0/4/1.1 and 0/0/4/1.2 respectively.
Summary of Contents for L1000 - 9000 - 0 MB RAM
Page 7: ...Contents vii Typical Installation Schedule 207 Site Inspection 208 Delivery Survey 212 ...
Page 8: ...Contents viii ...
Page 10: ...Tables x ...
Page 12: ...Figures xii ...
Page 14: ...xiv ...
Page 16: ...Chapter 1 Server Overview 2 ...
Page 17: ...Chapter 2 3 2 Server Unpacking and Installation ...
Page 37: ...Chapter 3 23 3 Installing Additional Components ...
Page 60: ...Chapter 3 Installing Additional Components Installing Disk Drives 46 ...
Page 61: ...Chapter 4 47 4 Cable Connections ...
Page 91: ...Chapter 5 77 5 Utilities ...
Page 98: ...Chapter 5 Utilities Configuring the Rev B Guardian Service Processor GSP 84 ...
Page 99: ...Chapter 6 85 6 Troubleshooting ...
Page 134: ...Chapter 6 Troubleshooting Fan Power Supply and Disk LED States 120 ...
Page 189: ...Appendix A 175 A Parts and Accessories ...