Chapter 3
Installing Additional Components
Installing Peripheral Component Interconnect (PCI) Cards
31
rp5470 PCI Card Slots
For rp5470 models, the 10 PCI I/O slots consist of Twin Turbo, Turbo, and non-Turbo slots. The following
illustration shows the PCI card slot layout.
•
Slots 1 and 2 are reserved for the rp54xx LAN/SCSI and GSP (Guardian Service Processor) Core I/O
cards, respectively. Slots 1 and 2 are non-Turbo slots. Non-Turbo slots share a single 250MB/s PCI bus
and are incapable of HotPlug functionality. The server must be turned off prior to removing or installing
the LAN/SCSI or GSP cards in these slots.
•
Slots 3 and 4 are non-Turbo slots. These two Non-Turbo slots share a single 250MB/s PCI bus, run at
33MHz and support 32 and 64-bit PCI cards. Non-Turbo slots are incapable of HotPlug functionality. The
server must be turned off prior to removing or installing PCI cards in these slots.
•
Slots 5 - 10 are Turbo slots. Each Turbo slot has a dedicated 250MB/s PCI bus, run at 66MHz and support
32 and 64-bit PCI cards. Turbo slots are HotPlug capable. Below each Turbo slot is a plastic PCI card
separator. The PCI card separator has two LEDs and a pull tab on the outer edge. The LED’s provide
power and status for the slot. The pull tab allows the PCI card to be easily removed.
•
Slots 11 and 12 are Twin Turbo slots. Each Twin Turbo slot has a dedicated 500MB/S PCI bus, runs at 66
MHz, and supports 32- and 64-bit PCI cards. Twin Turbo slots are HotPlug capable. Below each Twin
Turbo slot is a plastic PCI card separator. The PCI card separator has two LEDs and a pull tab on the
outer edge. The LED’s provide power and status for the slot and the pull tab allows the PCI card to be
easily removed.
rp5470 servers have access to all (1-12) slots.
rp5470 PCI Slots
Summary of Contents for L1000 - 9000 - 0 MB RAM
Page 7: ...Contents vii Typical Installation Schedule 207 Site Inspection 208 Delivery Survey 212 ...
Page 8: ...Contents viii ...
Page 10: ...Tables x ...
Page 12: ...Figures xii ...
Page 14: ...xiv ...
Page 16: ...Chapter 1 Server Overview 2 ...
Page 17: ...Chapter 2 3 2 Server Unpacking and Installation ...
Page 37: ...Chapter 3 23 3 Installing Additional Components ...
Page 60: ...Chapter 3 Installing Additional Components Installing Disk Drives 46 ...
Page 61: ...Chapter 4 47 4 Cable Connections ...
Page 91: ...Chapter 5 77 5 Utilities ...
Page 98: ...Chapter 5 Utilities Configuring the Rev B Guardian Service Processor GSP 84 ...
Page 99: ...Chapter 6 85 6 Troubleshooting ...
Page 134: ...Chapter 6 Troubleshooting Fan Power Supply and Disk LED States 120 ...
Page 189: ...Appendix A 175 A Parts and Accessories ...